About Typical VFD Motor Drive Control
6-10
KVAL Operation/Service Manual
About the VFD
A VFD (Variable Frequency Drive) takes the raw input from the 3 phase line voltage and converts
it by varying the frequency and voltage of the input voltage. Changes in the output voltage varies
speed and force of the motor. For example: A lower frequency will result in a slower speed.
The VFD converts the voltage but is “told what to do” by the PLC (Programical Logic Control-
ler). The output voltage is then sent to the motor. For a block diagram,
see
Figure
6- 22 on page
6-
9
.
VFD models vary in KVAL machines depending on where it is used, voltage requirements and
type of PLC used. This is a general view on the VFD. See the machine’s Electrical Print for
detailed information.
Line Voltage IN
Converted Signal OUT to Motor
Operation Panel:
Access to
manual operation VFD. This
panel can be used for trouble-
shooting purposes.
Fault
Errors
will be displayed if any
occur.
During normal operation the
Run
LED is lit or flickers and
the frequency of the motor is
displayed.
Control Circuit Board:
Con-
tains connections to PLC and
other control circuits.
Includes:
• Control input signals
• Speed Functions
• Relay Outputs
• Jumpers
• Output to reset switch
FIGURE 6- 23.
Sample of VFD
Summary of Contents for Edge-SS
Page 5: ...KVAL Edge SS Operation Service Manual ...
Page 12: ...KVAL Edge SS Line Operation Service Manual ...
Page 32: ...Safety Sign Off Sheet 1 20 KVAL Operation Service Manual ...
Page 35: ...Definitions 2 45 KVAL Operation Service Manual ...
Page 91: ...Definitions KVAL Operation Service Manual 2 56 ...
Page 109: ...System IT Administration 4 4 KVAL Operation Service Manual ...
Page 142: ...Collet Torque Values 5 33 KVAL Operation Service Manual ...
Page 143: ...Troubleshooting Electrical Problems 6 30 KVAL Operation Service Manual ...
Page 173: ......
Page 177: ......
Page 178: ......
Page 179: ......