Keyboard Controller Failure
The keyboard failed the self-test command. Check to see if the keyboard is
correctly plugged in. If the problem continues, and you have access to another
FlexPAC keyboard, try an alternative.
Keyboard Failure
The keyboard failed to respond to the RESET ID command.Check to see if the
keyboard is correctly plugged in. If the problem continues, and you have access
to another FlexPAC keyboard, try an alternative.
No Bootable Floppy Drive 0 Installed
No bootable floppy drive was detected. Possible solutions:
(1) Power down the system and check all appropriate connections, cables, etc.
(2) In configurations where no floppy drive is installed, run the SCU (System
Configuration Utility) and make sure the disk drive configuration option is set
to “None.”
(3) Replace the disk drive, if necessary.
No Interrupts from Timer 0
The periodic timer interrupt is not occurring.
RAM Parity Error at Location xxxx
A RAM parity error occurred at the specified (hexa-decimal) location.
6
■
Maintenance & Troubleshooting
6.16
Summary of Contents for FlexPAC
Page 1: ...FlexPAC Portable Add In Computer Document Revision 1 0...
Page 12: ......
Page 13: ...1 Getting Started...
Page 37: ...Figure 1 12 External Audio Jacks 1 Getting Started 1 24...
Page 38: ...2 System Description...
Page 48: ...3 Configuration...
Page 79: ...4 Display Drives...
Page 83: ...Figure 4 1 Removable Hard Disk Drive Option 4 Display Drives 4 4...
Page 87: ...Figure 4 4 Loading a CD 3 Inserted CD 4 Loading Tray 4 Display Drives 4 8...
Page 90: ...5 Expanding the FlexPAC...
Page 101: ...6 Maintenance Troubleshooting...
Page 107: ...Figure 6 1 Removable Fan Cover Grills 6 Maintenance Troubleshooting 6 6...
Page 125: ...6 Maintenance Troubleshooting 6 24...
Page 126: ...6 Maintenance Troubleshooting 6 25...
Page 127: ...A Appendix...