Ch.6 Web Maintenance Mode
< 168 >
DRYPRO Vstage MODEL 793 Installation Manual Ver.1.00 2004.11
6.1 Outline of Web Maintenance Mode
DRYPRO 793 is furnished with a Web maintenance mode, which allows maintenance on the device to be carried out
externally by connection to the Internet.
Using the Web maintenance mode allows the user to reference and make changes to settings from remote locations.
The Web maintenance mode may be operated from the Internet Explorer using PC that meets the requirements listed
below.
CPU
Pentium
3
500MHz minimum (800MHz minimum recommended)
Memory
128MB minimum (256MB minimum recommended)
Display
XGA (1024x768 bits 256 colors) or higher
OS
Windows 2000/XP
Browser
Internet Explorer 5.5 or higher
With "Cookie" capabilities
Environment that allows use of Java script. (If unsure, download and install
"j2re_1_3_1_win_I_exe" from the Sun Microsoft homepage
Select "Proxy Server not used" in the Internet Explorer settings.
- Although multiple web browsers may be activated on one external PC for
connection to multiple DRYPRO 793 units, multiple web browsers activated on one
external PC cannot be connected to the same DRYPRO 793 unit.
- A maximum of 16 web maintenance modes may be used simultaneously on the
network.
- Like the maintenance mode from the DRYPRO 793, printing and receipt of print
data from diagnostic devices is not possible while the Web maintenance mode is
active.
Print jobs remaining will be output after termination of the Web maintenance mode.
- Level 3 and service privilege cannot be used simultaneously on the operation panel
and in the Web maintenance mode.
PC Settings for the Web Maintenance Mode
1. Make the following Internet settings on the Internet Explorer.
- Enter checks under [Tools] - [Internet Options] - [Overall] - [Setup] - [Check for each
page display].
- Set [Tools] - [Internet Options] - [Security] - [Internet] - [Standard Level].
- [Tools] - [Internet Options] - [Security] - [Intranet] - [Standard Level].
- Invoke [Tools] - [Internet Options] - [Security] - [Preview Site] - [Site] - [Add following site to
zone], enter IP address of DRYPRO 793 and click the [OK] button.
2. Install Java Script version "1.3.1_09."
In cases where version 1.4 is installed, delete and install version "1.3.1_09."
Use of version 1.4 may render it impossible to properly use the Web maintenance
mode.
Version Check
The version installed may be checked as follows: [Control Panel] - [Adding and
Deleting Programs] - "Java 2 Runtime Environment xxx" ("xxx" represents the
version number.)
Deleting Version 1.4
[Control Panel] – [Adding and Deleting Programs] - "Java 2 Runtime Environment xxx - click
the [Delete] button.