252
381298/C
Processor Unit
•
Make and model
: Simrad Enix
•
Voltage requirement
: 115/230 Vac, 47 to 63 Hz, single phase, nominal
•
Maximum voltage deviation
: 15%
•
Maximum transient
: 20% of nominal voltage, recovery time 3 s
•
Power consumption
: 500 W @ 230 VAC (Approximately)
Operating Panel
Not applicable. This unit is not powered by AC mains.
Operating Panel Power Supply
•
Voltage requirement
: 115/230 Vac, 47 to 63 Hz, single phase, nominal
•
Maximum voltage deviation
: 15%
•
Maximum transient
: 20% of nominal voltage, recovery time 3 s
•
Power consumption
: 10 VA (Approximately)
Transceiver Unit
•
Voltage requirement
: 230 Vac / 47–63 Hz / single phase
•
Maximum voltage deviation
: 15%
•
Maximum transient
: 20% of nominal voltage, recovery time 3 s
•
Power consumption
: Approximately 600 VA
Related topics
385609 Processor Unit outline dimensions, page 223
Installing the Enix Processor Unit, page 118
Processor Unit description, page 20
204688 Operating Panel outline dimensions, page 227
Installing the Operating Panel, page 120
Cutout drawing for Operating Panel installation, page 121
Operating Panel description, page 22
Installing the Operating Panel Power Supply, page 122
Operating Panel Power Supply description, page 22
396280 Transceiver Unit outline dimensions, page 220
Installing the Transceiver Unit, page 123
Location of the mounting brackets, page 126
Installation of the mounting brackets, page 127
Transceiver Unit grounding, page 128
Transceiver Unit description, page 21
Simrad SN90
Summary of Contents for Simrad SN90
Page 2: ......
Page 117: ...381298 C 115 Related topics Installation summary page 65 Installing the transducer ...
Page 236: ...234 381298 C 372915 Clamping frame Simrad SN90 ...
Page 295: ......
Page 296: ... 2016Kongsberg Maritime ISBN 978 82 8066 179 1 ...
Page 297: ......