132
381298/C
Topside cable plan
The topside/bridge cables include those used to connect the SN90 Processor Unit
(computer) and the display to each other, to AC mains power, and to external devices.
One Ethernet cable is used to connect the Processor Unit to the Transceiver Unit.
C12*
C1
C14
SIMRAD
C7
C2
C3*
C4*
C13
C9
C5*
C8
C10*
C11*
C6
(CD010203_002_001)
A
B
C
E
D
A
Processor Unit
B
Display
C
Operating Panel
D
Operating Panel Power Supply
E
Uninterruptible Power Supply (UPS)
Cables identified with an asterisk (*) are system cables. These are provided with the
standard SN90 delivery.
The maximum length of the Ethernet cable is 100 meters. It is very important that a
high quality Ethernet cable is used. You must use CAT-5E STP (Shielded Twisted
Pair) quality or better. Using a cable with lower bandwidth capacity will reduce the
SN90 performance. Do not connect the Processor Unit to the Transceiver Unit using
the existing local area network.
Related topics
Read this first, page 130
List of SN90 cables, page 134
Cable procedures, page 136
Simrad SN90
Summary of Contents for Simrad SN90
Page 2: ......
Page 117: ...381298 C 115 Related topics Installation summary page 65 Installing the transducer ...
Page 236: ...234 381298 C 372915 Clamping frame Simrad SN90 ...
Page 295: ......
Page 296: ... 2016Kongsberg Maritime ISBN 978 82 8066 179 1 ...
Page 297: ......