381298/C
111
Procedure
1
Verify that all the required parts are available.
• Plug housing
• Lid with six M5 mounting bolts
• 32 bolts (M3x8) to mount the connectors
• Cable clamp with two M6x90 bolts
• Roxtec module
• Protective gasket
• Protective plate
• Six clamps
Note that the lid with the six mounting bolts represent a design change. Not all
plug houses have a separate lid.
2
Take the cable clamp, insert it into the plug housing, and mount it partially using the
two 90 mm bolts.
(CD010205_101_003)
A
Roxtec cable seal
B
Eight bolts to tighten the seal
C
Cable clamp inside the plug housing
D
Two M6x90 bolts for the cable clamp
E
Plug housing
F
Lid
3
Pull the cables through the Roxtec module.