381298/C
133
Sonar room cable plan
The Transceiver Unit cables include those used to connect the SN90 transceiver(s) to
AC mains power, and to the transducer(s).
C8
(CD010205_0109_001)
C16*
C17*
C15
C18*
A
Transceiver Unit
B
Uninterruptible Power Supply (UPS)
C
Transducer
D
Ethernet communication with the Processor Unit
Cables identified with an asterisk (*) are system cables. These are provided with the
standard SN90 delivery.
The maximum length of the Ethernet cable is 100 meters. It is very important that a
high quality Ethernet cable is used. You must use CAT-5E STP (Shielded Twisted
Pair) quality or better. Using a cable with lower bandwidth capacity will reduce the
SN90 performance. Do not connect the Processor Unit to the Transceiver Unit using
the existing local area network.
Related topics
Read this first, page 130
List of SN90 cables, page 134
Cable procedures, page 136
Summary of Contents for Simrad SN90
Page 2: ......
Page 117: ...381298 C 115 Related topics Installation summary page 65 Installing the transducer ...
Page 236: ...234 381298 C 372915 Clamping frame Simrad SN90 ...
Page 295: ......
Page 296: ... 2016Kongsberg Maritime ISBN 978 82 8066 179 1 ...
Page 297: ......