381298/C
109
Roxtec steps (Image from Roxtec
website)
The Roxtec system is available with a large
number of various modules and compression
units. It will also comply with screening and
EMC requirements.
Procedure
1
Cut an opening in the structure (bulkhead,
cabinet etc) you wish to penetrate.
The hole must be sized to fit one of
the standard rectangular or circular
frames provided by the sealing system
manufacturer.
Note
The chosen solution must comply with the
fire and/or pressure demands for the vessel.
If the sealing is to be used under water, both
pressure and material requirements must
be taken into consideration.
2
Mount the frame.
3
Pull the cable(s) through the frame.
In most cases the opening will be large
enough to accept the plugs on the cables.
4
Secure each cable with a square sealing
module.
5
Adjust the module to fit the cable’s outer
diameter.
6
When the required number of modules
are installed, tighten the assembly with a
compression unit.
Further requirements
For more information, and other installation procedures, refer to the documentation
provided by Roxtec (or your manufacturer of choice).
Related topics
Installation summary, page 65
Pulling the transducer cable through the sealing plate, page 102
Installing the transducer cables, page 104
Assembling the transducer plug, page 110