381298/C
99
•
Quantity
: Eight
•
Length
:
–
SN90
: 15 m (with transceiver plug mounted)
–
SN91
: 25 m (with transceiver plug mounted)
–
SN92
: 15 m
–
SN93
: 25 m
•
Minimum bending radius
:
–
Static
: 95 mm
–
Dynamic
: 243 mm
•
Tensile strength
: 3000 N
•
Outer sheet
: Polyurethane
Procedure
1
Prepare a cart or any other type of suitable transport vehicle.
2
Place a protective mat on the cart to safeguard the transducer face.
3
Open the shipping box.
Note
Be careful! Do not use heavy tools, and make sure that you do not damage the
transducer or any of the cables inside the crate.
4
Lift the transducer straight up and out of the box.
Note
DO NOT lift it by the cables! Support the cables during the lift to keep the
transducer body from tilting sideways.
5
Place the transducer on the cart for transport to the mounting location.