(G): When the quick coupler is installed
REMARK
• 2 persons are required to measure the dimensions (6) and the Angle (5) of the “Bucket Identification
Point”.
• The work equipment is lowered due to hydraulic drift when it is above the ground. Perform measuring
of “Bucket Identification Point” as making sure that the plumb (11) is vertical from time to time.
METHOD FOR INPUTTING BUCKET INFORMATION (TILT BUCKET)
Input the measured dimensions and angles.
Tap the inside of the white frame of dimension value to be input
again, and then the numeric keypad pops up. Input the numeric
value with it.
Measure the length dimension to mm unit, and angle to 0.1 °
unit.
You can input the numeric value within the range shown below.
• Numeric value (1)
Min: 0.00001 m to Max: 19.99999 m
• Numeric value (2)
Min: 0.00001 m to Max: 19.99999 m
• Numeric value (3)
Min: 0.0001 m to Max: 5.9999 m
• Numeric value (4)
Min: 0.0001 m to Max: 2.9999 m
• Angle (5)
Min: 0.01 ° to Max: 179.99 °
• Numeric value (6)
Min: 0.0001 m to Max: 5.9999 m
Check the input numeric value. If there is no problem, tap “Next” button.
If any numeric value or angle column is empty, even if “Next” button is pressed, it is invalid.
CONTROL BOX
SETTING
7-170
Summary of Contents for A31001
Page 12: ...LOCATION OF SAFETY LABELS Options are shown with marks in the figure SAFETY LABELS SAFETY 2 4...
Page 106: ......
Page 107: ...SPECIFICATIONS 5 1...
Page 110: ......
Page 116: ......
Page 117: ...SETTING 7 1...
Page 311: ...EXECUTIONS 8 1...
Page 376: ...PC360LCi 11 PC390LCi 11 HYDRAULIC EXCAVATOR Form No CEAM032703...