Operating and appliance data
© KEB, 2012-10
COMBIVERT F5-A, -E, -H
Page 7.1 - 11
7
Parameter
Addr.
R
PG
E
Min. value
Max. value
Res.
[?]
Default
ru.37
motorpoti actual value
0225h
RO
-
-
-100
100
0.01
%
-
The motorpoti-function in the KEB COMBIVERT imitates a mechanical, motor operated potentiometer. The
control occurs via 2 programmable inputs („poti up“ and „poti down“). The display is limited by oP.53/ 54. The
adjustment of the motorpoti is done with the parameters oP.50...oP.59 (also see chapt. 7.15.3 „Motorpoti“). By
way of the bus the motorpoti can be set to any chosen value between -100...100%. In addition to the inputs
the motorpoti can be operated with the keys „UP“ and „DOWN“. Then the rate of change is not constant.
Parameter
Addr.
R
PG
E
Min. value
Max. value
Res.
[?]
Default
ru.38
power module tempe-
rature
0226h
RO
-
-
0
150
1
°C
-
ru.38 shows the current power stage temperature of the inverter.
Parameter
Addr.
R
PG
E
Min. value
Max. value
Res.
[?]
Default
ru.39
Overload integrator
(E.OL)
0227h
RO
-
-
0
100
1
%
-
In order to preclude „E.OL“ - errors by too high load (load reduction in due time), the internal count of the OL-
counter can be made visible with this display. At 100 % the inverter switches off with error „E.OL“. The error
can be reset only after a cooling time (blinking display „E.nOL“).
Parameter
Addr.
R
PG
E
Min. value
Max. value
Res.
[?]
Default
ru.40
power on counter
0228h
RO
-
-
0
65535
1
h
-
The operating hours meter shows the time the inverter was switched on. The indicated value comprises all
operating phases. On reaching the maximum value (approx. 7.5 years) the display remains on the maximum
value.
Parameter
Addr.
R
PG
E
Min. value
Max. value
Res.
[?]
Default
ru.41 modulation on counter
0229h RO
-
-
0
65535
1
h
-
The modulation hours meter shows the time the inverter was active (power modules controlled). On reaching
the maximum value (approx. 7.5 years) the display remains on the maximum value.
Parameter
Addr.
R
PG
E
Min. value
Max. value
Res.
[?]
Default
ru.42
modulation grade
022Ah
RO
-
-
0
110
1
%
-
The modulation factor shows the output voltage in percent. 100 % correspond to the input voltage (no-load).
At a value of > 100 % the inverter works with overmodulation.
Parameter
Addr.
R
PG
E
Min. value
Max. value
Res.
[?]
Default
ru.43
timer 1 display
022Bh
RO
-
-
0
655,35
0.01
-
-
The count of the free-programmable timer 1 is indicated. The display is done either in seconds, in hours or in
slopes/100 (see LE.21). The counter can be adjusted to any chosen value by keyboard or bus. The program-
ming of the counter is done with the parameters LE.17...LE.21 (see also chapter 7.15 „Timer“).
Parameter
Addr.
R
PG
E
Min. value
Max. value
Res.
[?]
Default
ru.44
timer 2 display
022Ch RO
-
-
0
655,35
0.01
-
-
The count of the free-programmable timer 2 is indicated. The display is done either in seconds, in hours or in
slopes/100 (see LE.26). The counter can be adjusted to any chosen value by keyboard or bus. The program-
ming of the counter is done with the parameters LE.22...LE.26 (see also chapter 7.15 „Timer“).
Summary of Contents for COMBIVERT F5-A
Page 1: ...KEB COMBIVERT F5 A E H 4 4 APPLICATION MANUAL Mat No Rev 00F5AEA K440 1A...
Page 2: ...Page 1 1 2 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 4: ...Page 1 1 4 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 14: ...Page 1 1 14 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 20: ...Page 2 1 6 COMBIVERT F5 A E H KEB 2012 10 Product Overview...
Page 28: ...Page 3 1 8 COMBIVERT F5 A E H KEB 2012 10 Control Units...
Page 34: ...Page 4 1 6 COMBIVERT F5 A E H KEB 2012 10 Fundamentals...
Page 40: ...Page 4 2 6 COMBIVERT F5 A E H KEB 2012 10 Password input...
Page 42: ...Page 5 1 2 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Page 46: ...Page 5 1 6 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Page 70: ...Page 6 2 20 COMBIVERT F5 A E H KEB 2012 10 Start up...
Page 140: ...Page 7 3 44 COMBIVERT F5 A E H KEB 2012 10 Digital in and outputs...
Page 238: ...Page 7 7 12 COMBIVERT F5 A E H KEB 2012 10 Speed control...
Page 254: ...Page 7 8 16 COMBIVERT F5 A E H KEB 2012 10 Torque display and limiting...
Page 260: ...Page 7 9 6 COMBIVERT F5 A E H KEB 2012 10 Torque control...
Page 292: ...Page 7 11 26 COMBIVERT F5 A E H KEB 2012 10 Speed measurement...
Page 432: ...Page 7 14 14 COMBIVERT F5 A E H KEB 2012 10 Parameter sets...
Page 466: ...Page 7 15 34 COMBIVERT F5 A E H KEB 2012 10 Special functions...
Page 478: ...Page 7 16 12 COMBIVERT F5 A E H KEB 2012 10 CP Parameter definition...
Page 488: ...Page 8 1 10 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting...
Page 496: ...Page 9 1 8 COMBIVERT F5 A E H KEB 2012 10 General design...
Page 538: ...Page 11 1 28 COMBIVERT F5 A E H KEB 2012 10 Parameter...
Page 540: ...Page 12 1 2 COMBIVERT F5 A E H KEB 2008 02 Annex 12 1 1 Index 12 1 3...