Page 11.1 - 26
COMBIVERT F5-A, -E, -H
© KEB, 2012-10
Parameter
Parameter
Addr.
R
P
E
Lower limit
Upper limit
Default
Step
Unit
See on page
SY.43 control word (long)
002Bh
appl
np
E
-2^31
2^311
0
1
hex
7.1 - 4,7.1 - 21,7.3 - 12,7.3 -
SY.44 status word (long)
002Ch
RO
np
---
-2^31
2^311
0
1
hex
7.1 - 4,7.1 - 21,7.13 - 16,7.1
Sy.45 drive mode reference value
002Dh
appl
np
---
0
n * 4095
n * 1500
n *
0.125
rpm
5.1-4
Sy.46 drive mode rotation
002Eh
appl
np
---
0
15
0
1
hex
SY.50 control word (low)
0032h
appl
np
E
0
65535
0
1
hex
7.1 - 4,7.1 - 21,7.3 - 12,7.3 -
14,7.4 - 7,7.4 - 11,7.4 - 12,7
,7.13 - 14,7.13 - 15,7.13 - 1,
Sy. 51 status word (low)
0033h
RO
np
---
0
65535
0
1
hex
7.1-4, 7.1-20, 7.1-21,
7.3-19, 7.13-15, 7.13-17,
7.13-38, 10.1-12, 10.1-13
SY.52 set speed value
0034h
appl
np
---
-32000;
-64000;
-128000
32000; 64000;
128000
0
1; 2; 4
rpm
5.1-4, 7.1-4, 7.1-21, 7.4-4,
10.1-13
SY.53 actual speed value
0035h
RO
np
---
-32000;
-64000;
-128000
32000; 64000;
128000
0
1; 2; 4
rpm
5.1-4, 7.1-4, 7.1-21, 10.1-
13
Sy.54 message time stamps
0036h
cp-ro
np
---
0
255
0
1
hex
Sy.56 start display address
0038h
cp-ro
np
E
0
7FFFH
0209h
1
hex
7.1-4, 7.1-22
Sy.57 watchdog time address
0039h
cp-ro
np
---
-2
-1
-2
1
hex
Sy.58
proc. read data 5 defin.
003Ah
appl
np
E
-1
7FFFH
-1
1
hex
Sy.59 proc. read data 5 set
003Bh
appl
np
E
1
128
1
1
---
Sy.60
proc. read data 6 defin.
003Ch
appl
np
E
-1
7FFFH
-1
1
hex
Sy.61 proc. read data 6 set
003Dh
appl
np
E
1
128
1
1
---
Sy.62
proc. read data 7 defin.
003Eh
appl
np
E
-1
7FFFH
-1
1
hex
SY.63 proc. read data 7 set
003Fh
appl
np
E
1
128
1
1
---
SY.64
proc. read data 8 defin.
0040h
appl
np
E
-1
7FFFH
-1
1
hex
Sy.65 proc. read data 8 set
0041h
appl
np
E
1
128
1
1
---
Sy.66 proc. write data 5 def.
0042h
appl
np
E
-1
7FFFH
-1
1
hex
Sy.67 Proc. write data 5 set
0043h
appl
np
E
1
255
255
1
---
Sy.68 proc. write data 6 def.
0044h
appl
np
E
-1
7FFFH
-1
1
hex
Sy.69 Proc. write data 6 set
0045h
appl
np
E
1
255
255
1
---
Sy.70 proc. write data 7 def.
0046h
appl
np
E
-1
7FFFH
-1
1
hex
Sy.71 Proc. write data 7 set
0047h
appl
np
E
1
255
255
1
---
Sy.72 proc. write data 8 def.
0048h
appl
np
E
-1
7FFFH
-1
1
hex
Sy.73 Proc. write data 8 set
0049h
appl
np
E
1
255
255
1
---
Sy.74 Proc. data 1-4 size
004Ah
appl
np
E
0
65535
0
1
hex
Sy.75 Proc. data 5-8 size
004Bh
appl
np
E
0
65535
0
1
hex
SY.77 Control word S4
004Dh
appl
np
E
0
65535
0
1
hex
SY.78 Status word S4
004Eh
appl
np
---
0
65535
0
1
hex
SY.79 Status word 1 PROFIdrive
004Fh
appl
np
---
0
65535
0
1
hex
7.1-22
SY.80 Status word 2 PROFIdrive
0050h
appl
np
---
0
65535
0
1
hex
7.1-22
ud. 01 Password
0801h
cp-ro
np o.P.
0
9999
Application
1
---
6.2-3, 7.16-12
ud.02 Control type
0802h
appl
np
E
0
15
0
1
---
5.1 - 5,6.2 - 9,7.1 - 5,7.2 - 10
,7.2 - 11,7.2 - 12,7.4 - 4,7.4 -
5,7.4 - 6,7.4 - 18,7.4 - 21,7.4
- 22,7.4 - 24,7.12 - 81,7.15 -
ud.02 Control type
0802h
appl
np
E
0
15
8
1
---
ud. 04 Auto store state
0804h
appl
np
---
0: off
1: on
1: on
1
---
ud. 05 auto store
0805h
appl
np
---
0: off
2
1: on
1
---
10.1-10
ud. 09 drive-mode-control
0809h
appl
np
---
0
11
0
1
---
ud.15 CP selector
080Fh
appl
np
E
1
36
1
1
---
7.16 - 3,7.16 - 4,7.16 - 6,7.1
ud.16 cp address
0810h
appl
np
E
-1: off
7FFFH
CP def.
1
hex
7.16 - 3,7.16 - 4,7.16 - 6,7.1
ud.17 cp set norm
0811h
appl
np
E
1
8191
1
1
---
7.16-3, 7.16-6
further on next side
Summary of Contents for COMBIVERT F5-A
Page 1: ...KEB COMBIVERT F5 A E H 4 4 APPLICATION MANUAL Mat No Rev 00F5AEA K440 1A...
Page 2: ...Page 1 1 2 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 4: ...Page 1 1 4 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 14: ...Page 1 1 14 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 20: ...Page 2 1 6 COMBIVERT F5 A E H KEB 2012 10 Product Overview...
Page 28: ...Page 3 1 8 COMBIVERT F5 A E H KEB 2012 10 Control Units...
Page 34: ...Page 4 1 6 COMBIVERT F5 A E H KEB 2012 10 Fundamentals...
Page 40: ...Page 4 2 6 COMBIVERT F5 A E H KEB 2012 10 Password input...
Page 42: ...Page 5 1 2 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Page 46: ...Page 5 1 6 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Page 70: ...Page 6 2 20 COMBIVERT F5 A E H KEB 2012 10 Start up...
Page 140: ...Page 7 3 44 COMBIVERT F5 A E H KEB 2012 10 Digital in and outputs...
Page 238: ...Page 7 7 12 COMBIVERT F5 A E H KEB 2012 10 Speed control...
Page 254: ...Page 7 8 16 COMBIVERT F5 A E H KEB 2012 10 Torque display and limiting...
Page 260: ...Page 7 9 6 COMBIVERT F5 A E H KEB 2012 10 Torque control...
Page 292: ...Page 7 11 26 COMBIVERT F5 A E H KEB 2012 10 Speed measurement...
Page 432: ...Page 7 14 14 COMBIVERT F5 A E H KEB 2012 10 Parameter sets...
Page 466: ...Page 7 15 34 COMBIVERT F5 A E H KEB 2012 10 Special functions...
Page 478: ...Page 7 16 12 COMBIVERT F5 A E H KEB 2012 10 CP Parameter definition...
Page 488: ...Page 8 1 10 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting...
Page 496: ...Page 9 1 8 COMBIVERT F5 A E H KEB 2012 10 General design...
Page 538: ...Page 11 1 28 COMBIVERT F5 A E H KEB 2012 10 Parameter...
Page 540: ...Page 12 1 2 COMBIVERT F5 A E H KEB 2008 02 Annex 12 1 1 Index 12 1 3...