Page 7.12 - 12
COMBIVERT F5-A, -E, -H
© KEB, 2012-10
Posi- and synchronous operating
7.12.2.8
Approach to reference point / stop at index 0
By setting bit 5 (stop at index 0 = 32: on), it can be programmed that the drive after completion approach to
reference point moves automatically (i.e. without „start positioning“ signal) to the position of index 0.
PS.20 "approach to reference point ramp time" specifies
the acceleration / deceleration values for the posi-
tioning to index 0. The maximum profile speed for positioning is determined for Index 0
by the value of PS.25
"index speed".
The drive remains at that Position. The setting "continue profile = yes” from index 0 is ignored.
PS.14 Mode of position reference
Bit
Meaning
Value
Explanation
5
Stop at index 0
0: off
After approach to reference point the drive stops at the reference point.
32: on
after approach to reference point, the position from Index 0 is driven to.
The following figure shows an approach to reference point with stop at the null signal left of the reference point
switch and automatic positioning to index 0:
1
2
3
4
5
6
7
8
ru.54: actual po-
sition
ru.02 setpoint
speed
Target window not
reached
search for ref. active
Reference switch signal
Start approach to refe-
rence point
1:
Start of approach to reference point
2.:
Run-on at the reference point switch
2 - 3:
Reversing and free driving of the reference switch
3 - 4:
Stop left of the reference switch
4:
Start of the positioning to the null signal of the encoder
5 - 6:
Waiting out the damping period after reaching the null signal
6:
Referencing of the actual position:ru.54 is overwritten with the value of PS.17 "reference point"
6 - 7:
Positioning to the target position of index 0 with the ramp time from parameter PS.20
7:
Reaching of the target position
8:
Approach to reference point finished
Summary of Contents for COMBIVERT F5-A
Page 1: ...KEB COMBIVERT F5 A E H 4 4 APPLICATION MANUAL Mat No Rev 00F5AEA K440 1A...
Page 2: ...Page 1 1 2 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 4: ...Page 1 1 4 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 14: ...Page 1 1 14 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 20: ...Page 2 1 6 COMBIVERT F5 A E H KEB 2012 10 Product Overview...
Page 28: ...Page 3 1 8 COMBIVERT F5 A E H KEB 2012 10 Control Units...
Page 34: ...Page 4 1 6 COMBIVERT F5 A E H KEB 2012 10 Fundamentals...
Page 40: ...Page 4 2 6 COMBIVERT F5 A E H KEB 2012 10 Password input...
Page 42: ...Page 5 1 2 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Page 46: ...Page 5 1 6 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Page 70: ...Page 6 2 20 COMBIVERT F5 A E H KEB 2012 10 Start up...
Page 140: ...Page 7 3 44 COMBIVERT F5 A E H KEB 2012 10 Digital in and outputs...
Page 238: ...Page 7 7 12 COMBIVERT F5 A E H KEB 2012 10 Speed control...
Page 254: ...Page 7 8 16 COMBIVERT F5 A E H KEB 2012 10 Torque display and limiting...
Page 260: ...Page 7 9 6 COMBIVERT F5 A E H KEB 2012 10 Torque control...
Page 292: ...Page 7 11 26 COMBIVERT F5 A E H KEB 2012 10 Speed measurement...
Page 432: ...Page 7 14 14 COMBIVERT F5 A E H KEB 2012 10 Parameter sets...
Page 466: ...Page 7 15 34 COMBIVERT F5 A E H KEB 2012 10 Special functions...
Page 478: ...Page 7 16 12 COMBIVERT F5 A E H KEB 2012 10 CP Parameter definition...
Page 488: ...Page 8 1 10 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting...
Page 496: ...Page 9 1 8 COMBIVERT F5 A E H KEB 2012 10 General design...
Page 538: ...Page 11 1 28 COMBIVERT F5 A E H KEB 2012 10 Parameter...
Page 540: ...Page 12 1 2 COMBIVERT F5 A E H KEB 2008 02 Annex 12 1 1 Index 12 1 3...