Network components
© KEB, 2012-10
COMBIVERT F5-A, -E, -H
Page 10.1 - 11
10
10.1.9.8
Status and control word
The control word is used for the status control of the inverter via bus. The actual state of the inverter can be
read out with the status word.
The control word low is bit-coded designed as follows.
SY.50: Control word low
Bit
Function
Value
Description
0
Control re-
lease
1: ST
This bit is only effective if di.01 „select signal source“ bit 0 is
set. Then the AND operation of this bit with di.02 „digital input
setting“ bit 0 is valid.
1
Automatic
2: RST
An error reset is executed when changing from not activated (0)
to activated (2).
2
Start / stop
0: Stop
Direction of rotation release or the „start “(„run “) command can
be given via the control word, if oP.01 „rotation source“ contains
the values 6, 8, 9 or 10.
4: Start
3
Clockwise /
counter clock-
wise rotation
0: Clockwise
rotation
If oP.01 „rotation source“ contains the values 8 or 9, the direction
of rotation is preset via this bit.
8: Counter-clock-
wise rotation
4...6
Parameter set
0: Set 0
Selection of the active parameter set, if in Fr.02 „parameter set
source“ the value „5: control word (SY.50)“ is programmed
16: Set 1
32: Set 2
48: Set 3
64: Set 4
80: Set 5
96: Set 6
112: Set 7
7
reserved
8
Fast stop on
/ off
256: Fast stop
Releases fast stop (OR operation with further fast stop sources).
9
Start approach
to reference
point
512: Start ap-
proach to refe-
rence point
Change of not activated (0) to activated (512) starts approach
to reference point.
10
Start Positio-
ning
1024: Start Posi-
tioning
Change of not activated (0) to activated (1024) starts the posi-
tioning.
11
Interruption
2048: Interruption
Change of not activated (0) to activated (2048) stops the positio-
ning (drive is stopped with ramp according to positioning profile)
12, 13
Operating
mode
0: off
Selection of the operating mode via the control word.
Only valid if in PS.00 „posi/syn mode“ in bits 0..2 value „7: via
control word“ is programmed)
4096: Synchro-
nous running
8192: positioning
12288: Contou-
ring control
14, 15 reserved
Summary of Contents for COMBIVERT F5-A
Page 1: ...KEB COMBIVERT F5 A E H 4 4 APPLICATION MANUAL Mat No Rev 00F5AEA K440 1A...
Page 2: ...Page 1 1 2 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 4: ...Page 1 1 4 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 14: ...Page 1 1 14 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 20: ...Page 2 1 6 COMBIVERT F5 A E H KEB 2012 10 Product Overview...
Page 28: ...Page 3 1 8 COMBIVERT F5 A E H KEB 2012 10 Control Units...
Page 34: ...Page 4 1 6 COMBIVERT F5 A E H KEB 2012 10 Fundamentals...
Page 40: ...Page 4 2 6 COMBIVERT F5 A E H KEB 2012 10 Password input...
Page 42: ...Page 5 1 2 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Page 46: ...Page 5 1 6 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Page 70: ...Page 6 2 20 COMBIVERT F5 A E H KEB 2012 10 Start up...
Page 140: ...Page 7 3 44 COMBIVERT F5 A E H KEB 2012 10 Digital in and outputs...
Page 238: ...Page 7 7 12 COMBIVERT F5 A E H KEB 2012 10 Speed control...
Page 254: ...Page 7 8 16 COMBIVERT F5 A E H KEB 2012 10 Torque display and limiting...
Page 260: ...Page 7 9 6 COMBIVERT F5 A E H KEB 2012 10 Torque control...
Page 292: ...Page 7 11 26 COMBIVERT F5 A E H KEB 2012 10 Speed measurement...
Page 432: ...Page 7 14 14 COMBIVERT F5 A E H KEB 2012 10 Parameter sets...
Page 466: ...Page 7 15 34 COMBIVERT F5 A E H KEB 2012 10 Special functions...
Page 478: ...Page 7 16 12 COMBIVERT F5 A E H KEB 2012 10 CP Parameter definition...
Page 488: ...Page 8 1 10 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting...
Page 496: ...Page 9 1 8 COMBIVERT F5 A E H KEB 2012 10 General design...
Page 538: ...Page 11 1 28 COMBIVERT F5 A E H KEB 2012 10 Parameter...
Page 540: ...Page 12 1 2 COMBIVERT F5 A E H KEB 2008 02 Annex 12 1 1 Index 12 1 3...