Implementation of the stops:
If the drive has reached position 1 (PS.24 of block 1) or position 2 (PS.24 of block 2), it shall remain
there 500ms or 1200ms and then automatically carry out the next positioning step. To implement this
sequence, the timer functionality must be utilised. With reaching of the target of Index 0 or Index 1,
Timer 1 must be started. The drive then remains at the target position until the timer has exceeded the
time level of 500ms and 1200ms, respectively. Exceeding the time level triggers a "start positioning".
With the start of the next positioning, the timer must be stopped and reset.
The start of the timer must be triggered by a software input. Input IA was chosen here.
→ LE17: timer 1 start inp. sel. = 256: IA
IA is always then set if software output OA is set.
On reaching of the target of Index 1 or Index 2, Timer 1 must be started (i.e., the software output OA must be
set).
Output OA must also be set if the switching condition act.. index = 1 or act.. index = 2 and, simultaneously, the
condition "target reached" are met
→
do.00: Condition 0 = 54: target window reached (positioning)
M0 = SB0 = target reached
→ do.16: Condition selection for flag 0 = 1: SB0
→
do.01: Condition 1 = 72: act. position index = level
SB1: Index = 1
→
LE.01: Comparison level 1 = 1,00
→
do.02: Condition 2 = 72: act. position index = level
SB2: Index = 2
→
LE.02: Comparison level 2 = 2,00
→ do.19: Condition selection for flag 3 = 6: SB1+SB2
M3 = SB1 or SB2
→
do.37: Flag selection for OA = 9: M0+M3
OA = M0 and M3
→
do.41: AND conn. for outputs = 16: OA
When the timer has counted 1500ms (for index 1) or 1200ms (for index 2), a "start positioning" signal shall
be generated.
As input for the "start positioning" signal, software input IB is used.
→
PS.29 = 576: I3 (X2A.12) + IB
Output OB must therefore be set, when the switching conditions index = 1 (SB1) and timer 1 > 500ms, or
index = 2 (SB2) and timer 1 > 1200ms, are met.
→
do.03: Condition 3 = 37: Timer 1 > level
SB3: Timer > 500 ms
→
LE.03: Comparison level 1 = 0,50
→
do.04: Condition 4 = 37: Timer 1 > level
SB4: Timer > 1200 ms
→
LE.02: Comparison level 2 = 1,20
→ do.17: Condition selection for flag 1 = 10: SB1+ SB3
M1 = SB1 and SB3
→ do.18: Condition selection for flag 2 = 20: SB2+ SB4
M2 = SB2 and SB4
→
do.24: SB AND/OR conjunction = 6: M1+M2
→
do38: Flag selection for OB = 6: M1+M2
OB = M1 or M2
The resetting of the timer must be triggered by a software input. Input IC was chosen here.
→
LE.19: timer 1 start inp. sel. = 1024: IC
Page 7.12 - 50
COMBIVERT F5-A, -E, -H
© KEB, 2012-10
Posi- and synchronous operating
Summary of Contents for COMBIVERT F5-A
Page 1: ...KEB COMBIVERT F5 A E H 4 4 APPLICATION MANUAL Mat No Rev 00F5AEA K440 1A...
Page 2: ...Page 1 1 2 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 4: ...Page 1 1 4 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 14: ...Page 1 1 14 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 20: ...Page 2 1 6 COMBIVERT F5 A E H KEB 2012 10 Product Overview...
Page 28: ...Page 3 1 8 COMBIVERT F5 A E H KEB 2012 10 Control Units...
Page 34: ...Page 4 1 6 COMBIVERT F5 A E H KEB 2012 10 Fundamentals...
Page 40: ...Page 4 2 6 COMBIVERT F5 A E H KEB 2012 10 Password input...
Page 42: ...Page 5 1 2 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Page 46: ...Page 5 1 6 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Page 70: ...Page 6 2 20 COMBIVERT F5 A E H KEB 2012 10 Start up...
Page 140: ...Page 7 3 44 COMBIVERT F5 A E H KEB 2012 10 Digital in and outputs...
Page 238: ...Page 7 7 12 COMBIVERT F5 A E H KEB 2012 10 Speed control...
Page 254: ...Page 7 8 16 COMBIVERT F5 A E H KEB 2012 10 Torque display and limiting...
Page 260: ...Page 7 9 6 COMBIVERT F5 A E H KEB 2012 10 Torque control...
Page 292: ...Page 7 11 26 COMBIVERT F5 A E H KEB 2012 10 Speed measurement...
Page 432: ...Page 7 14 14 COMBIVERT F5 A E H KEB 2012 10 Parameter sets...
Page 466: ...Page 7 15 34 COMBIVERT F5 A E H KEB 2012 10 Special functions...
Page 478: ...Page 7 16 12 COMBIVERT F5 A E H KEB 2012 10 CP Parameter definition...
Page 488: ...Page 8 1 10 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting...
Page 496: ...Page 9 1 8 COMBIVERT F5 A E H KEB 2012 10 General design...
Page 538: ...Page 11 1 28 COMBIVERT F5 A E H KEB 2012 10 Parameter...
Page 540: ...Page 12 1 2 COMBIVERT F5 A E H KEB 2008 02 Annex 12 1 1 Index 12 1 3...