Setpoint, rotation- and ramp setting
© KEB, 2012-10
COMBIVERT F5-A, -E, -H
Page 7.4 - 13
7
7.4.6
Setpoint limits
Following limit values can be preadjusted:
Figure 7.4.5 Setpoint limits
+n [rpm]
4000
oP.7*
1
(oP.6)
oP.6
oP.14
oP.10
oP.15*
1
(oP.14)
oP.11*
1
(oP.10)
+100
-100
-4000
absolute max.setpoint
forward
max. setpoint forward
min. setpoint forward
Setpoint [%]
Setpoint [%]
min. setpoint reverse
max. setpoint reverse
absolute max. setpoint reverse
-n [rpm]
*1
If the value "=For" is adjusted in these parameters (limit values rotation direction reverse), then the adjusted
values for rotation direction forward (oP.06, oP.10 and oP.14) are valid.
Min./ max. reference values (oP.06, oP.07, oP.10, oP.11)
In case of analog and percentaged setpoint adjustment in percent the minimal and maximal frequencies form
the characteristic for the frequency calculation (0% = min. reference; 100% = max. reference). In case of digi-
tal setpoint adjustment or fixed value the minimal and maximal frequencies limit the setpoint. Separate limits
can be adjusted for both rotation directions. If the value "For" is adjusted for rotation direction "Reverse", then
the values for "Forward" are valid.
Setting range:
oP.06: 0...4000 rpm
Default: 0 rpm
oP.10: 0...4000 rpm
Default: 2100 rpm
oP.07: =For, 0...4000 rpm
Default: =For
oP.11: =For, 0...4000 rpm
Default: = or
Absolute maximum references (oP.14, oP.15)
After the min./max. references the setpoint is limited by the absolute max. references and then output to the
ramp generator. Since the analog setpoint is always calculated in relation to the max. reference (oP.10, oP.11)
it is possible (despite different absolute max. references) to adjust the characteristic of the analog setpoint with
the same ascent for both rotation directions (see Fig.7.4.5.a). If in oP.15 value "=For" is adjusted, the absolute
maximal speed of oP.14 is valid for both directions of rotation.
Summary of Contents for COMBIVERT F5-A
Page 1: ...KEB COMBIVERT F5 A E H 4 4 APPLICATION MANUAL Mat No Rev 00F5AEA K440 1A...
Page 2: ...Page 1 1 2 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 4: ...Page 1 1 4 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 14: ...Page 1 1 14 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 20: ...Page 2 1 6 COMBIVERT F5 A E H KEB 2012 10 Product Overview...
Page 28: ...Page 3 1 8 COMBIVERT F5 A E H KEB 2012 10 Control Units...
Page 34: ...Page 4 1 6 COMBIVERT F5 A E H KEB 2012 10 Fundamentals...
Page 40: ...Page 4 2 6 COMBIVERT F5 A E H KEB 2012 10 Password input...
Page 42: ...Page 5 1 2 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Page 46: ...Page 5 1 6 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Page 70: ...Page 6 2 20 COMBIVERT F5 A E H KEB 2012 10 Start up...
Page 140: ...Page 7 3 44 COMBIVERT F5 A E H KEB 2012 10 Digital in and outputs...
Page 238: ...Page 7 7 12 COMBIVERT F5 A E H KEB 2012 10 Speed control...
Page 254: ...Page 7 8 16 COMBIVERT F5 A E H KEB 2012 10 Torque display and limiting...
Page 260: ...Page 7 9 6 COMBIVERT F5 A E H KEB 2012 10 Torque control...
Page 292: ...Page 7 11 26 COMBIVERT F5 A E H KEB 2012 10 Speed measurement...
Page 432: ...Page 7 14 14 COMBIVERT F5 A E H KEB 2012 10 Parameter sets...
Page 466: ...Page 7 15 34 COMBIVERT F5 A E H KEB 2012 10 Special functions...
Page 478: ...Page 7 16 12 COMBIVERT F5 A E H KEB 2012 10 CP Parameter definition...
Page 488: ...Page 8 1 10 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting...
Page 496: ...Page 9 1 8 COMBIVERT F5 A E H KEB 2012 10 General design...
Page 538: ...Page 11 1 28 COMBIVERT F5 A E H KEB 2012 10 Parameter...
Page 540: ...Page 12 1 2 COMBIVERT F5 A E H KEB 2008 02 Annex 12 1 1 Index 12 1 3...