Troubleshooting
© KEB, 2012-10
COMBIVERT F5-A, -E, -H
Page 8.1 - 7
8
Display
COMBIVIS
Value Meaning
E.OL2
Error ! overload 2
19
Occurs if the standstill constant current is exceeded (see technical
data and overload characteristics). The error can only be reset if the
cooling time has elapsed and E.nOL2 is displayed.
E.OP
Error ! overvoltage
1
Voltage in the DC-link circuit too high. Occurs if the DC-link voltage
exceeds the permissible value. Causes:
poor controller adjustment (overshooting)
input voltage too high
interference voltages at the input
deceleration ramp too short
braking resistor defective or too small
E.OS
Error ! over speed
58
The speed is outside the defined limits. (can also occur on exceeding
of the absolute speed referring to EMF = EMF wrong (servo drives).
E.PFC
Error ! PFC
33
Error in the power factor control.
E.PrF
Error ! prot. rot. for.
46
The drive has driven onto the right limit switch. Programmed response
“Error, restart after reset” (see chapter 6.7 “Response to errors or
warning messages”).
E.Prr
Error ! prot. rot. rev.
47
The drive has driven onto the left limit switch. Programmed response
“Error, restart after reset” (see chapter 6.7 “Response to errors or
warning messages”).
E. Pu
Error ! power unit
12
Error: General power circuit fault
E.Puci
Error ! power circuit unknown
49
Error: During the initialization the power circuit could not be recognized
or was identified as invalid.
E.Puch
Error ! power unit changed
50
Error: Power circuit identification was changed; the error can be
reset by writing on SY.03 at valid power circuit. If the value displayed
in SY.03 is written, only the power-circuit dependent parameters
are reinitialized. If any other value is written, then the default set is
loaded. A power-on-reset is necessary on some systems after writing
of SY.03.
E.PUCO
Error ! power unit
communication
22
Error: Parameter value could not be written to the power circuit.
Acknowledgement from LT <> OK
E.PUIN
Error ! power circuit coding
14
Error: Software version for power circuit and control card are different.
Error cannot be reset (only at F5-G B-housing)
E.SbuS
Error ! bus synchron
23
Sychronization over sercos-bus not possible. Programmed response
“Error, restart after reset”.
E.SCL
ERROR! speed controller
limit
25
Speed controller limit reached
E.SEt
Error ! set
39
It has been attempted to select a locked parameter set. Programmed
response “Error, restart after reset”.
E.SLF
Error ! Software limit switch
forward
44
The target position lies outside of the limit defined with the right
software limit switch. Programmed response “Error, restart after
reset”.
E.SLr
Error ! software limit switch
reverse
45
The target position lies outside of the limit defined with the left software
limit switch. Programmed response “Error, restart after reset”.
further on next side
Summary of Contents for COMBIVERT F5-A
Page 1: ...KEB COMBIVERT F5 A E H 4 4 APPLICATION MANUAL Mat No Rev 00F5AEA K440 1A...
Page 2: ...Page 1 1 2 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 4: ...Page 1 1 4 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 14: ...Page 1 1 14 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 20: ...Page 2 1 6 COMBIVERT F5 A E H KEB 2012 10 Product Overview...
Page 28: ...Page 3 1 8 COMBIVERT F5 A E H KEB 2012 10 Control Units...
Page 34: ...Page 4 1 6 COMBIVERT F5 A E H KEB 2012 10 Fundamentals...
Page 40: ...Page 4 2 6 COMBIVERT F5 A E H KEB 2012 10 Password input...
Page 42: ...Page 5 1 2 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Page 46: ...Page 5 1 6 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Page 70: ...Page 6 2 20 COMBIVERT F5 A E H KEB 2012 10 Start up...
Page 140: ...Page 7 3 44 COMBIVERT F5 A E H KEB 2012 10 Digital in and outputs...
Page 238: ...Page 7 7 12 COMBIVERT F5 A E H KEB 2012 10 Speed control...
Page 254: ...Page 7 8 16 COMBIVERT F5 A E H KEB 2012 10 Torque display and limiting...
Page 260: ...Page 7 9 6 COMBIVERT F5 A E H KEB 2012 10 Torque control...
Page 292: ...Page 7 11 26 COMBIVERT F5 A E H KEB 2012 10 Speed measurement...
Page 432: ...Page 7 14 14 COMBIVERT F5 A E H KEB 2012 10 Parameter sets...
Page 466: ...Page 7 15 34 COMBIVERT F5 A E H KEB 2012 10 Special functions...
Page 478: ...Page 7 16 12 COMBIVERT F5 A E H KEB 2012 10 CP Parameter definition...
Page 488: ...Page 8 1 10 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting...
Page 496: ...Page 9 1 8 COMBIVERT F5 A E H KEB 2012 10 General design...
Page 538: ...Page 11 1 28 COMBIVERT F5 A E H KEB 2012 10 Parameter...
Page 540: ...Page 12 1 2 COMBIVERT F5 A E H KEB 2008 02 Annex 12 1 1 Index 12 1 3...