7.12.3.2
Synchronous mode / premise
For the synchronous module, the incremental signals from the encoder of the master drive must be passed on
to the slave.
START
STOP
FUNC.
SPEED
ENTER
F/R
ANTRIEBSTECHNI
K
START
STOP
FUNC.
SPEED
ENTER
F/R
ANTRIEBSTECHNI
K
START
STOP
FUNC.
SPEED
ENTER
F/R
ANTRIEBSTECHNI
K
START
STOP
FUNC.
SPEED
ENTER
F/R
ANTRIEBSTECHNI
K
X3B X3A
X3B
X3B
X3A
X3A
3
~
3
~
3
~
3
~
speed
closed-loop
master drive
speed
closed-loop
slave drive
open-loop
master drive
speed
closed-loop
slave drive
If more than one slave is connected, there are two different variations for assembling the master-slave-chain:
direct transfer of the signals from the output of the master encoder interface to all slaves.
START
STOP
FUNC.
SPEED
ENTER
F/R
ANTRIEBSTECHNI
K
START
STOP
FUNC.
SPEED
ENTER
F/R
ANTRIEBSTECHNI
K
START
STOP
FUNC.
SPEED
ENTER
F/R
ANTRIEBSTECHNI
K
START
STOP
FUNC.
SPEED
ENTER
F/R
ANTRIEBSTECHNI
K
X3B X3A
X3B
X3B
X3A
X3A
3
~
3
~
3
~
3
~
speed
closed-loop
master drive
speed
closed-loop
slave drive1
speed
closed-loop
slave drive 2
speed
closed-loop
slave drive X
Ec.20 encoder operating mode = 1
(input + without terminating resistor)
Ec.20 encoder operating mode = 0
(input + with terminating resistor)
Posi- and synchronous operating
© KEB, 2012-10
COMBIVERT F5-A, -E, -H
Page 7.12 - 15
7
Summary of Contents for COMBIVERT F5-A
Page 1: ...KEB COMBIVERT F5 A E H 4 4 APPLICATION MANUAL Mat No Rev 00F5AEA K440 1A...
Page 2: ...Page 1 1 2 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 4: ...Page 1 1 4 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 14: ...Page 1 1 14 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 20: ...Page 2 1 6 COMBIVERT F5 A E H KEB 2012 10 Product Overview...
Page 28: ...Page 3 1 8 COMBIVERT F5 A E H KEB 2012 10 Control Units...
Page 34: ...Page 4 1 6 COMBIVERT F5 A E H KEB 2012 10 Fundamentals...
Page 40: ...Page 4 2 6 COMBIVERT F5 A E H KEB 2012 10 Password input...
Page 42: ...Page 5 1 2 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Page 46: ...Page 5 1 6 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Page 70: ...Page 6 2 20 COMBIVERT F5 A E H KEB 2012 10 Start up...
Page 140: ...Page 7 3 44 COMBIVERT F5 A E H KEB 2012 10 Digital in and outputs...
Page 238: ...Page 7 7 12 COMBIVERT F5 A E H KEB 2012 10 Speed control...
Page 254: ...Page 7 8 16 COMBIVERT F5 A E H KEB 2012 10 Torque display and limiting...
Page 260: ...Page 7 9 6 COMBIVERT F5 A E H KEB 2012 10 Torque control...
Page 292: ...Page 7 11 26 COMBIVERT F5 A E H KEB 2012 10 Speed measurement...
Page 432: ...Page 7 14 14 COMBIVERT F5 A E H KEB 2012 10 Parameter sets...
Page 466: ...Page 7 15 34 COMBIVERT F5 A E H KEB 2012 10 Special functions...
Page 478: ...Page 7 16 12 COMBIVERT F5 A E H KEB 2012 10 CP Parameter definition...
Page 488: ...Page 8 1 10 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting...
Page 496: ...Page 9 1 8 COMBIVERT F5 A E H KEB 2012 10 General design...
Page 538: ...Page 11 1 28 COMBIVERT F5 A E H KEB 2012 10 Parameter...
Page 540: ...Page 12 1 2 COMBIVERT F5 A E H KEB 2008 02 Annex 12 1 1 Index 12 1 3...