Page 7.15 - 6
COMBIVERT F5-A, -E, -H
© KEB, 2012-10
Special functions
7.15.2
Energy saving function
The energy saving function allows the lowering or raising of the current output voltage. In accordance with the
activation conditions defined in uF.6, the voltage valid according to the V/Hz-characteristic is changed in per
-
cent onto the energy saving level (uF.07).
However, the maximal output voltage cannot be higher than the input voltage even if the value is > 100 %. The
function is used for example in cyclic executed load/no-load applications. During the no-load phase the speed
is maintained, but energy is saved as a result of the voltage reduction.
uF.7
t
uf.07
Energy saving factor
0,0…130,0 % (default 70 %)
uf.06
Energy saving mode
Bit 0...3 Energy saving function / activation
0
generally off
1
generally active
2
at actual value = setpoint
3
by digital input
4
at clockwise rotation
5
at counter clockwise rotation
6
by constant run clockwise rotation
7
by constant run counter clockwise rotation
8...15 reserved
Bit 4...6 Energy saving function / ramp time
Default time ca. 1,6 s
0
Default time
16
Default time / 2
32
Default time / 4
48
Default time / 8
64
Default time / 16
f
actual
; n
actual
; U
A
Hysteresis
Example: uF.6 = 2, uF.7 = 50 %
uF.08 Energy saving function
input selection
0...4095 (Default 0)
also see 7.3
„Digital inputs“
f
set
; n
set
Summary of Contents for COMBIVERT F5-A
Page 1: ...KEB COMBIVERT F5 A E H 4 4 APPLICATION MANUAL Mat No Rev 00F5AEA K440 1A...
Page 2: ...Page 1 1 2 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 4: ...Page 1 1 4 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 14: ...Page 1 1 14 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 20: ...Page 2 1 6 COMBIVERT F5 A E H KEB 2012 10 Product Overview...
Page 28: ...Page 3 1 8 COMBIVERT F5 A E H KEB 2012 10 Control Units...
Page 34: ...Page 4 1 6 COMBIVERT F5 A E H KEB 2012 10 Fundamentals...
Page 40: ...Page 4 2 6 COMBIVERT F5 A E H KEB 2012 10 Password input...
Page 42: ...Page 5 1 2 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Page 46: ...Page 5 1 6 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Page 70: ...Page 6 2 20 COMBIVERT F5 A E H KEB 2012 10 Start up...
Page 140: ...Page 7 3 44 COMBIVERT F5 A E H KEB 2012 10 Digital in and outputs...
Page 238: ...Page 7 7 12 COMBIVERT F5 A E H KEB 2012 10 Speed control...
Page 254: ...Page 7 8 16 COMBIVERT F5 A E H KEB 2012 10 Torque display and limiting...
Page 260: ...Page 7 9 6 COMBIVERT F5 A E H KEB 2012 10 Torque control...
Page 292: ...Page 7 11 26 COMBIVERT F5 A E H KEB 2012 10 Speed measurement...
Page 432: ...Page 7 14 14 COMBIVERT F5 A E H KEB 2012 10 Parameter sets...
Page 466: ...Page 7 15 34 COMBIVERT F5 A E H KEB 2012 10 Special functions...
Page 478: ...Page 7 16 12 COMBIVERT F5 A E H KEB 2012 10 CP Parameter definition...
Page 488: ...Page 8 1 10 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting...
Page 496: ...Page 9 1 8 COMBIVERT F5 A E H KEB 2012 10 General design...
Page 538: ...Page 11 1 28 COMBIVERT F5 A E H KEB 2012 10 Parameter...
Page 540: ...Page 12 1 2 COMBIVERT F5 A E H KEB 2008 02 Annex 12 1 1 Index 12 1 3...