Digital in- and outputs
© KEB, 2012-10
COMBIVERT F5-A, -E, -H
Page 7.3 - 29
7
19: Power-off start
20: Safe memory
A digital input which can release fast storage of all para-
meters in the EEPROM is selected with this parameter.
See page „10.1.9.7
Automatisches
Speichern
(ud.05), Status Datenspeicherung (ud.04);“ auf Seite
<?>
21: Flow monitor
1)
the column „Fct. Para“ indicates the function-related parameter, corresponding to the value in di.11...di.22
* is scanned with 250µs
7.3.12 Software-ST and locking of the control release
di.36 software ST, di.37 locking ST, di.38 turn off ST delay time
The function is switched off, if no input is selected in di.36. ST can not be selected as software ST or input for
locking.
With the locking function the control release can be controlled in case of voltage failure (even if the controlled
PLC is failure) as long as e.g. Power off needs for stopping the drive.
Condition: terminal ST must be bridged !
Switching off an input (selection in di.36) is decelerated for the time adjusted in di.38. Within this time the lo-
cking input (selection in di.37) must be active in order to secure the function.
A software input e.g. (IA-ID) can be assigned with the function Power Off (do.00...do.07 = 17, switching condi-
tion for OA-OD) as locking input.
Summary of Contents for COMBIVERT F5-A
Page 1: ...KEB COMBIVERT F5 A E H 4 4 APPLICATION MANUAL Mat No Rev 00F5AEA K440 1A...
Page 2: ...Page 1 1 2 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 4: ...Page 1 1 4 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 14: ...Page 1 1 14 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 20: ...Page 2 1 6 COMBIVERT F5 A E H KEB 2012 10 Product Overview...
Page 28: ...Page 3 1 8 COMBIVERT F5 A E H KEB 2012 10 Control Units...
Page 34: ...Page 4 1 6 COMBIVERT F5 A E H KEB 2012 10 Fundamentals...
Page 40: ...Page 4 2 6 COMBIVERT F5 A E H KEB 2012 10 Password input...
Page 42: ...Page 5 1 2 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Page 46: ...Page 5 1 6 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Page 70: ...Page 6 2 20 COMBIVERT F5 A E H KEB 2012 10 Start up...
Page 140: ...Page 7 3 44 COMBIVERT F5 A E H KEB 2012 10 Digital in and outputs...
Page 238: ...Page 7 7 12 COMBIVERT F5 A E H KEB 2012 10 Speed control...
Page 254: ...Page 7 8 16 COMBIVERT F5 A E H KEB 2012 10 Torque display and limiting...
Page 260: ...Page 7 9 6 COMBIVERT F5 A E H KEB 2012 10 Torque control...
Page 292: ...Page 7 11 26 COMBIVERT F5 A E H KEB 2012 10 Speed measurement...
Page 432: ...Page 7 14 14 COMBIVERT F5 A E H KEB 2012 10 Parameter sets...
Page 466: ...Page 7 15 34 COMBIVERT F5 A E H KEB 2012 10 Special functions...
Page 478: ...Page 7 16 12 COMBIVERT F5 A E H KEB 2012 10 CP Parameter definition...
Page 488: ...Page 8 1 10 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting...
Page 496: ...Page 9 1 8 COMBIVERT F5 A E H KEB 2012 10 General design...
Page 538: ...Page 11 1 28 COMBIVERT F5 A E H KEB 2012 10 Parameter...
Page 540: ...Page 12 1 2 COMBIVERT F5 A E H KEB 2008 02 Annex 12 1 1 Index 12 1 3...