Digital in- and outputs
© KEB, 2012-10
COMBIVERT F5-A, -E, -H
Page 7.3 - 35
7
do.00...do.07: Switching conditions
V a -
lue
Function
Description
47
Ramp output display (ru.2) >
level
Amount ramp output display (ru.02) > switching level
48
Apparent current (ru.15) > level
Apparent current (ru.15) > switching level
49
Clockwise rotation
current rotation direction clockwise rotation and counter clockwise rotation,
respectively (only set if ramp generator is active.
50
Counter clockwise rotation
51
OL2 warning
Upon exceeding of level Pn.09 (default 80 %) the overload warning OL2 is
output. The performance in case of a warning can be adjusted with Pn.8
(response to OL-warning).
52
Current regulator limit reached
Current and speed controller in limit (not in v/f characteristic controlled ope-
ration).
53
Speed control at the limit
54
Target window reached
The position profile is completed (
ru.56 = ru.61) and the drive is in the range
of +/- PS.30 / 2 (target window) around the target position ru.61.
55
Current position > level
ru.54 „actual position“ > switching level (observe scaling factor of the levels:
1.00 = 100 increments).
56
positioning active
Positioning is active, but the set position ru.56 has not yet reached the target
position ru.61. The output is deactivated, as soon as the calculated position
profile has reached the target position (
ru.56 „set position“ = ru.61 „target
position“), even if the drive has not reached the target window.
57
position not reachable
The position is inaccessible from the current speed under the restrictions
of the adjusted deceleration and S-curve times or a new "start positioning"
command was sent during the deceleration ramp.
58
Profile processing active
This output switching condition is needed for the follow-up positioning.
The output is set if the result of all selected inputs is 1. The internal state
of the inputs (displayed in
ru.22 „internal input state“) is significant for the
linkage.
The output is set with „start positioning“ and only deactivated if
ru.56 „set position“ has reached the last block of the target position.
. (In parameter PS.26 „index/ next“ of the last block value „ -1: PS.28“ must
be entered).
further on next side
Summary of Contents for COMBIVERT F5-A
Page 1: ...KEB COMBIVERT F5 A E H 4 4 APPLICATION MANUAL Mat No Rev 00F5AEA K440 1A...
Page 2: ...Page 1 1 2 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 4: ...Page 1 1 4 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 14: ...Page 1 1 14 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 20: ...Page 2 1 6 COMBIVERT F5 A E H KEB 2012 10 Product Overview...
Page 28: ...Page 3 1 8 COMBIVERT F5 A E H KEB 2012 10 Control Units...
Page 34: ...Page 4 1 6 COMBIVERT F5 A E H KEB 2012 10 Fundamentals...
Page 40: ...Page 4 2 6 COMBIVERT F5 A E H KEB 2012 10 Password input...
Page 42: ...Page 5 1 2 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Page 46: ...Page 5 1 6 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Page 70: ...Page 6 2 20 COMBIVERT F5 A E H KEB 2012 10 Start up...
Page 140: ...Page 7 3 44 COMBIVERT F5 A E H KEB 2012 10 Digital in and outputs...
Page 238: ...Page 7 7 12 COMBIVERT F5 A E H KEB 2012 10 Speed control...
Page 254: ...Page 7 8 16 COMBIVERT F5 A E H KEB 2012 10 Torque display and limiting...
Page 260: ...Page 7 9 6 COMBIVERT F5 A E H KEB 2012 10 Torque control...
Page 292: ...Page 7 11 26 COMBIVERT F5 A E H KEB 2012 10 Speed measurement...
Page 432: ...Page 7 14 14 COMBIVERT F5 A E H KEB 2012 10 Parameter sets...
Page 466: ...Page 7 15 34 COMBIVERT F5 A E H KEB 2012 10 Special functions...
Page 478: ...Page 7 16 12 COMBIVERT F5 A E H KEB 2012 10 CP Parameter definition...
Page 488: ...Page 8 1 10 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting...
Page 496: ...Page 9 1 8 COMBIVERT F5 A E H KEB 2012 10 General design...
Page 538: ...Page 11 1 28 COMBIVERT F5 A E H KEB 2012 10 Parameter...
Page 540: ...Page 12 1 2 COMBIVERT F5 A E H KEB 2008 02 Annex 12 1 1 Index 12 1 3...