Page 7.11 - 10
COMBIVERT F5-A, -E, -H
© KEB, 2012-10
Speed measurement
7.11.6
Encoder identifier
Before start-up the inverter must be adjusted to the used encoder.
Encoder interface 1 / 2 (Ec.00, Ec.10)
Ec.00 displays the installed encoder interface 1; Ec.10 displays theencoder interface 2. The values correspond
to following interfaces:
Ec.00, Ec.10: Encoder interface 1/ 2
Value Description
0
no
1
TTL-Incremental encoder input
2
Incremental encoder output 5 V TTL
3
Incremental encoder input and output direct
(non-divisible with Ec.27; switchable in- output with Ec.20)
4
Incremental encoder input and output TTL (switchable with Ec.20)
5
Initiator
6
Synchronous serial interface (SSI)
7
Resolver
8
Tacho
9
Incremental encoder output TTL (from resolver over channel 2)
10
Incremental encoder output TTL
11
Hiperface
12
Incremental encoder input 24 V HTL
13
Incremental encoder input TTL with error detection
14
SinCos encoder input
15
Incremental encoder input 24 V HTL with error detection (push-pull)
16
ENDAT
17
Incremental encoder input 24 V HTL with error detection
18
Analog option ±10 V
19
Reslover
20
SSI sincos
21
Overspeed limiter
22
UVW-Interface
23
Inc. emulation 10-30V
24
Inc. emulation 10-30V
25
Overspeed limiter HTL
26
Incremental encoder input TTL with error detection 5V supply terminal
27
Incremental encoder input HTL-push-pull terminal block with error detection
28
Endat/BiSS (switchable with Ec.62)
29
Incremental encoder output TTL variable
30
Position via Ec.28
In case of an invalid encoder identification, error „E.Hyb“ is indicated and the measured value is displayed
inverted in Ec.00/Ec.10.
On changing the encoder interface the error „
E.HybC“ is indicated. The change is confirmed by
writing on pa-
rameter Ec.00 or Ec.10 and the default values for the new interface are loaded. From version 4.2 the message
is acknowledged with error reset (terminal ST or RST).
Summary of Contents for COMBIVERT F5-A
Page 1: ...KEB COMBIVERT F5 A E H 4 4 APPLICATION MANUAL Mat No Rev 00F5AEA K440 1A...
Page 2: ...Page 1 1 2 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 4: ...Page 1 1 4 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 14: ...Page 1 1 14 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 20: ...Page 2 1 6 COMBIVERT F5 A E H KEB 2012 10 Product Overview...
Page 28: ...Page 3 1 8 COMBIVERT F5 A E H KEB 2012 10 Control Units...
Page 34: ...Page 4 1 6 COMBIVERT F5 A E H KEB 2012 10 Fundamentals...
Page 40: ...Page 4 2 6 COMBIVERT F5 A E H KEB 2012 10 Password input...
Page 42: ...Page 5 1 2 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Page 46: ...Page 5 1 6 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Page 70: ...Page 6 2 20 COMBIVERT F5 A E H KEB 2012 10 Start up...
Page 140: ...Page 7 3 44 COMBIVERT F5 A E H KEB 2012 10 Digital in and outputs...
Page 238: ...Page 7 7 12 COMBIVERT F5 A E H KEB 2012 10 Speed control...
Page 254: ...Page 7 8 16 COMBIVERT F5 A E H KEB 2012 10 Torque display and limiting...
Page 260: ...Page 7 9 6 COMBIVERT F5 A E H KEB 2012 10 Torque control...
Page 292: ...Page 7 11 26 COMBIVERT F5 A E H KEB 2012 10 Speed measurement...
Page 432: ...Page 7 14 14 COMBIVERT F5 A E H KEB 2012 10 Parameter sets...
Page 466: ...Page 7 15 34 COMBIVERT F5 A E H KEB 2012 10 Special functions...
Page 478: ...Page 7 16 12 COMBIVERT F5 A E H KEB 2012 10 CP Parameter definition...
Page 488: ...Page 8 1 10 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting...
Page 496: ...Page 9 1 8 COMBIVERT F5 A E H KEB 2012 10 General design...
Page 538: ...Page 11 1 28 COMBIVERT F5 A E H KEB 2012 10 Parameter...
Page 540: ...Page 12 1 2 COMBIVERT F5 A E H KEB 2008 02 Annex 12 1 1 Index 12 1 3...