Speed measurement
© KEB, 2012-10
COMBIVERT F5-A, -E, -H
Page 7.11 - 23
7
Attention: if the control release is still set, the drive starts to run automatically.
•
Error encoder 1
If no data can be read out from the encoder (value 97), „32: ERROR! encoder 1“ (E.Enc1) is released. At F5-S
the error can be reset either by writing of a system position in Ec.02 or by system position trimming.
•
Error enocder interface
Error „52: ERROR! encoder interface“ (E.HYb) only occurs, if either the control board or the encoder interface is
defective, or the voltage supply for the encoder interface is short-circuited by a defective encoder cable (e.g.).
Ec.38 encoder 1 r/w (electronic motor name plate)
Data can be stored and read out in some absolute encoders (e.g. Endat, Hiperface). Thus an „electronic name
plate“ can be stored for the motor/encoder system.
If an inverter is connected the
first time with an encoder which contains an electronic name plate, this is auto
-
matically read out, if „data load when switching on = 4: automatic “ is adjusted in Ec.38 (factory setting at F5-S).
KEB servo motors with electronic name plates already contain the complete motor data.
Ec.38: Encoder 1 r/w
Bit
Meaning
Value
Explanation
0
read data
0: reading not active
Activates the reading, value is set to 0
afterwards.
1: reading activated
1
store data
0: storing not active
Activates the storing, value is set to 0
afterwards (Supervisor-password pro-
tected)
2: storing activated
2
load data during switching
on
0: not automatically
Activates the automatic data load of the
inverter at the first
start-up
4: automatically
3, 4
data group/ selection
0: system and application
(all)
Motor data, Ec.01, Ec.02, cS.19 and
Ec.03
8: System
only motor data, Ec.01 and Ec.02
16: only Ec.02
only Ec.02
Summary of Contents for COMBIVERT F5-A
Page 1: ...KEB COMBIVERT F5 A E H 4 4 APPLICATION MANUAL Mat No Rev 00F5AEA K440 1A...
Page 2: ...Page 1 1 2 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 4: ...Page 1 1 4 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 14: ...Page 1 1 14 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 20: ...Page 2 1 6 COMBIVERT F5 A E H KEB 2012 10 Product Overview...
Page 28: ...Page 3 1 8 COMBIVERT F5 A E H KEB 2012 10 Control Units...
Page 34: ...Page 4 1 6 COMBIVERT F5 A E H KEB 2012 10 Fundamentals...
Page 40: ...Page 4 2 6 COMBIVERT F5 A E H KEB 2012 10 Password input...
Page 42: ...Page 5 1 2 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Page 46: ...Page 5 1 6 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Page 70: ...Page 6 2 20 COMBIVERT F5 A E H KEB 2012 10 Start up...
Page 140: ...Page 7 3 44 COMBIVERT F5 A E H KEB 2012 10 Digital in and outputs...
Page 238: ...Page 7 7 12 COMBIVERT F5 A E H KEB 2012 10 Speed control...
Page 254: ...Page 7 8 16 COMBIVERT F5 A E H KEB 2012 10 Torque display and limiting...
Page 260: ...Page 7 9 6 COMBIVERT F5 A E H KEB 2012 10 Torque control...
Page 292: ...Page 7 11 26 COMBIVERT F5 A E H KEB 2012 10 Speed measurement...
Page 432: ...Page 7 14 14 COMBIVERT F5 A E H KEB 2012 10 Parameter sets...
Page 466: ...Page 7 15 34 COMBIVERT F5 A E H KEB 2012 10 Special functions...
Page 478: ...Page 7 16 12 COMBIVERT F5 A E H KEB 2012 10 CP Parameter definition...
Page 488: ...Page 8 1 10 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting...
Page 496: ...Page 9 1 8 COMBIVERT F5 A E H KEB 2012 10 General design...
Page 538: ...Page 11 1 28 COMBIVERT F5 A E H KEB 2012 10 Parameter...
Page 540: ...Page 12 1 2 COMBIVERT F5 A E H KEB 2008 02 Annex 12 1 1 Index 12 1 3...