Parameter
© KEB, 2012-10
COMBIVERT F5-A, -E, -H
Page 11.1 - 27
10
11
Parameter
Addr.
R
P
E
Lower limit
Upper limit
Default
Step
Unit
See on page
ud.18 divisor display norm
0812h
appl
P
E
-32767
32767
1
1
---
7.16 - 5,7.16 - 6,7.16 - 7,7.1
ud.19 multiplier display norm
0813h
appl
P
E
-32767
32767
1
1
---
7.16-7, 7.16-8, 7.16-9
ud.20 offset display norm
0814h
appl
P
E
-32767
32767
0
1
---
7.16-7, 7.16-8, 7.16-9
ud.21 ctrl. display norm
0815h
appl
P
E
0
1791
0
1
---
7.16-6, 7.16-7, 7.16-8
ud. 22 PP selector
0816h
appl
np
E
0
47
0
1
---
7.16-12
ud.23 PP address
0817h
appl
np
E
-1: off
7FFFH
-1: off
1
hex
7.16-12
ud.24 PP properties
0818h
appl
np
E
1
2^20-1
1
1
---
7.16-4, 7.16-12
ud. 25 PP write multiplier
0819h
appl
np
---
-32767
32767
1
1
---
ud. 26 PP write shifter
081Ah
appl
np
---
0
48
0
1
---
ud. 27 PP read multiplier
081Bh
appl
np
---
-32767
32767
1
1
---
ud. 28 PP read shifter
081Ch
appl
np
---
0
48
0
1
---
ud.29 PP offset
081Dh
appl
np
---
-2^31+1
2^31-1
0
1
---
ud.30 PP upper limit
081Eh
appl
np
---
-2^31+1
2^31-1
1
1
---
ud. 31 PP lower limit
081Fh
appl
np
---
-2^31+1
2^31-1
0
1
---
uf.00
Rated frequency
0500h
appl
P
---
0
n * 400
n * 50 ; 60
n *
0.0125
Hz
5.1-4, 6.2-4, 7.5-4, 7.5-6,
7.5-9
uf.01
Boost
0501h
appl
P
---
0.0
25.5
LTK
0.1
%
6.2-4, 7.5-4, 7.5-9,
7.15-22
uf.02
Additional frequency
0502h
appl
P
---
n * -0.0125:
parab.
n * 400
0: linear
n *
0.0125
Hz
5.1-4, 7.5-5, 7.5-9
uf.03
Additional voltage
0503h
appl
P
---
0.0
100.0
0.0
0.1
%
7.5-5, 7.5-9
uf.04
Delta boost
0504h
appl
P
---
0.0
25.5
0.0
0.1
%
7.5-4
uF.05 Delta boost time
0505h
appl
P
---
0.00
10.00
0.00
0.01
s
7.5-4
uf.06
energy saving mode
0506h
appl
P
---
0
79
0
1
---
7.5-7, 7.5-11, 7.15-6
uf.06
energy saving mode
0506h
appl
P
---
0
127
0
1
---
uf.07
energy saving factor
0507h
appl
P
---
0.0
130.0
70.0
0.1
%
7.5-7, 7.15-6
uF.08 energy saving input sel.
0508h
appl
np
E
0
4095
0
1
---
7.3 - 10,7.3 - 11,7.5 - 7,7.5 - 1
uf.09
Voltage stabilization
0509h
appl
np
E
1
1120: off
1120: off
1
V
7.5 - 5,7.5 - 6,7.5 - 9,7.5 - 12
,7.5 - 13,7.6 - 5,7.13 - 33,7.
uF.10 Max. voltage mode
050Ah
appl
P
---
0
3
0
1
---
7.5-4, 7.5-5
uF.11 Carrier frequency
050Bh
appl
P
E
1
LTK
LTK
1
---
7.5-7, 7.10-5, 7.10-6
uF.11 Carrier frequency
050Bh
appl
P
E
0
LTK
LTK
1
---
uF.12 base block time
050Ch
RO
np
---
0.05
10.00
LTK
0.01
s
7.13-16, 7.13-17
uF.13 base block voltage level
050Dh
RO
np
---
1
50
LTK
1
%
7.13-17
uF.14 Transistor on delay time
050Eh
RO
np
---
0
LTK
LTK
0.05
µs
uF.15 hardw. curr. lim. mode
050Fh
appl
np
E
0
2
1
1
---
6.2 - 11,6.2 - 15,6.2 - 18,6.2
- 20,7.8 - 4,7.8 - 7,7.10 - 4,7
uF.16
Autoboost configuration
0510h
appl
P
---
0
3
0
1
---
7.5-9, 7.5-11
uF.17 Autoboost gain
0511h
appl
P
---
0.00
2.50
1.20
0.01
---
7.5-9, 7.5-11
uF.18 deadtime comp. mode
0512h
appl
np
E
0
3
0
1
---
6.2 - 11,6.2 - 15,6.2 - 20,7.5
- 21,7.5 - 23,7.6 - 12,7.6 - 18
uF.21
Dead time compensation off
input selection
0515h
appl
np
E
0
4095
0
1
---
7.3-10, 7.3-12, 7.5-23, 7.6-
12
uF.22
Dead time e-compensation
limit
0516h
sup
np
---
0.00
10.00
0.00
0.01
µs
uF.23
Dead time e-compensation
factor
0517h
sup
np
---
0
32000
0
1
---
uF.24 deadtime comp. PT1 time
0518h
appl
np
---
0.000
4095.938
0.000
0.063
ms
uF.25 dead time soft on/off
0519h
appl
np
---
0: off
1024
0: off
1.000
ms
Summary of Contents for COMBIVERT F5-A
Page 1: ...KEB COMBIVERT F5 A E H 4 4 APPLICATION MANUAL Mat No Rev 00F5AEA K440 1A...
Page 2: ...Page 1 1 2 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 4: ...Page 1 1 4 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 14: ...Page 1 1 14 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 20: ...Page 2 1 6 COMBIVERT F5 A E H KEB 2012 10 Product Overview...
Page 28: ...Page 3 1 8 COMBIVERT F5 A E H KEB 2012 10 Control Units...
Page 34: ...Page 4 1 6 COMBIVERT F5 A E H KEB 2012 10 Fundamentals...
Page 40: ...Page 4 2 6 COMBIVERT F5 A E H KEB 2012 10 Password input...
Page 42: ...Page 5 1 2 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Page 46: ...Page 5 1 6 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Page 70: ...Page 6 2 20 COMBIVERT F5 A E H KEB 2012 10 Start up...
Page 140: ...Page 7 3 44 COMBIVERT F5 A E H KEB 2012 10 Digital in and outputs...
Page 238: ...Page 7 7 12 COMBIVERT F5 A E H KEB 2012 10 Speed control...
Page 254: ...Page 7 8 16 COMBIVERT F5 A E H KEB 2012 10 Torque display and limiting...
Page 260: ...Page 7 9 6 COMBIVERT F5 A E H KEB 2012 10 Torque control...
Page 292: ...Page 7 11 26 COMBIVERT F5 A E H KEB 2012 10 Speed measurement...
Page 432: ...Page 7 14 14 COMBIVERT F5 A E H KEB 2012 10 Parameter sets...
Page 466: ...Page 7 15 34 COMBIVERT F5 A E H KEB 2012 10 Special functions...
Page 478: ...Page 7 16 12 COMBIVERT F5 A E H KEB 2012 10 CP Parameter definition...
Page 488: ...Page 8 1 10 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting...
Page 496: ...Page 9 1 8 COMBIVERT F5 A E H KEB 2012 10 General design...
Page 538: ...Page 11 1 28 COMBIVERT F5 A E H KEB 2012 10 Parameter...
Page 540: ...Page 12 1 2 COMBIVERT F5 A E H KEB 2008 02 Annex 12 1 1 Index 12 1 3...