Motor data and controller adjustments of the asynchronous motor
© KEB, 2012-10
COMBIVERT F5-A, -E, -H
Page 7.5 - 25
7
Resolution mode
dS.21
max. dS.22
4000 rpm
1/12 rated speed
1 s
8000 rpm
1/12 rated speed
2 s
16000 rpm
1/12 rated speed
4 s
32000 rpm
1/12 rated speed
8 s
64000 rpm
1/12 rated speed
16 s
128000 rpm
1/12 rated speed
32 s
•
Leakage inductance:
Measurement of the leakage inductance can lead to wrong values, if the inductance of the motor has a
pronounced current dependence. The current has a „bell-shaped“ curve at setting of sine-wave voltage.
This can often be observed at spindle motors. The magnetising current can be watched via Combivis in
ru.87 during the rotor
resistance measurement, to find out whether the motor to be
start up is concerned.
Depending on the deviation of the current from the sine form the inductance is reduced to 85..70% of the
identified
value.
•
Check current controller adjustments
A correction of the
current controller adjustment is eventually necessary if the identified leakage in
-
ductance (ds.07) is < 1,4mH:
ds.00 = ds.00_def * 1,0…1,5
ds.01 = ds.01_def * 1,5…2
Control to model currents:
The motor model (dS.04 bit 0) must be active for this. Control to the model current (dS.18 bit 3) has the advan-
tage that
disturbances of the measured currents enter filtered to the motor model and thus the calculated
model
current and the current control are smoother. The disadvantage is in the danger that the drive could change
to OC when there is a difference between measured and calculated current. Thus pay special attention to the
identification of the equivalent circuit
data.
Observer:
The observer (dS.18 bit5) adjusts the model currents dependent on the measured currents by the adjusted
factor in parameter dS.23 „observer factor".
Square-law load torque characteristic:
If the drive shall be accelerated at torque limit, it is mandatory necessary that the max. breakdown torque is not
exceeded. For this parameter (dS.03 bit 1) must be activated and the breakdown torque must be entered at
corner speed (dr.18) in parameter dr.16.
The corner speed (dr.18) should be set to rated speed (dr.01). If the breakdown torque should not be arise from
the data sheet, the breakdown torque must be calculated from the equivalent circuit data.
Rough formula : Mk = 2.0 * Mn
Mk = breakdown torque (dr.16)
Mn = rated torque (dr.14)
Summary of Contents for COMBIVERT F5-A
Page 1: ...KEB COMBIVERT F5 A E H 4 4 APPLICATION MANUAL Mat No Rev 00F5AEA K440 1A...
Page 2: ...Page 1 1 2 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 4: ...Page 1 1 4 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 14: ...Page 1 1 14 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 20: ...Page 2 1 6 COMBIVERT F5 A E H KEB 2012 10 Product Overview...
Page 28: ...Page 3 1 8 COMBIVERT F5 A E H KEB 2012 10 Control Units...
Page 34: ...Page 4 1 6 COMBIVERT F5 A E H KEB 2012 10 Fundamentals...
Page 40: ...Page 4 2 6 COMBIVERT F5 A E H KEB 2012 10 Password input...
Page 42: ...Page 5 1 2 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Page 46: ...Page 5 1 6 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Page 70: ...Page 6 2 20 COMBIVERT F5 A E H KEB 2012 10 Start up...
Page 140: ...Page 7 3 44 COMBIVERT F5 A E H KEB 2012 10 Digital in and outputs...
Page 238: ...Page 7 7 12 COMBIVERT F5 A E H KEB 2012 10 Speed control...
Page 254: ...Page 7 8 16 COMBIVERT F5 A E H KEB 2012 10 Torque display and limiting...
Page 260: ...Page 7 9 6 COMBIVERT F5 A E H KEB 2012 10 Torque control...
Page 292: ...Page 7 11 26 COMBIVERT F5 A E H KEB 2012 10 Speed measurement...
Page 432: ...Page 7 14 14 COMBIVERT F5 A E H KEB 2012 10 Parameter sets...
Page 466: ...Page 7 15 34 COMBIVERT F5 A E H KEB 2012 10 Special functions...
Page 478: ...Page 7 16 12 COMBIVERT F5 A E H KEB 2012 10 CP Parameter definition...
Page 488: ...Page 8 1 10 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting...
Page 496: ...Page 9 1 8 COMBIVERT F5 A E H KEB 2012 10 General design...
Page 538: ...Page 11 1 28 COMBIVERT F5 A E H KEB 2012 10 Parameter...
Page 540: ...Page 12 1 2 COMBIVERT F5 A E H KEB 2008 02 Annex 12 1 1 Index 12 1 3...