Page 7.15 - 22
COMBIVERT F5-A, -E, -H
© KEB, 2012-10
Special functions
The diameter signal of 0% corresponds to the minimum diameter of the reel bale (dmin).
The output speed of the ramp generator (ru.02) is not changed in this case.
A diameter signal of 100% corresponds to the maximum diameter of the reel bale (dmax).
The ratio of minimum to maximum diameter (dmin/dmax) must be known in order to be able to calculate the
required speed change.
The ratio of minimum to maximum diameter (dmin/dmax) is preset by way of oP.49 and can be adjusted within
the range of 0,010...0,990 with a resolution of 0,001.
The corrected output speed of the ramp generator is determined as follows:
fn_Ramp
fn_Setting:
=
–––––––––––––––
1+DS • (1/oP.49-1)
fn_Ramp:
Output frequency/speed of ramp generator
fn_presetting:
Corrected output frequency/speed
DS:
Diameter signal 0…100 % (0…1)
oP.49:
(d
min
/d
max
)
Rate of change of the diameter signal
The rate of change of the diameter signal can be limited by a ramp generator.
Parameter oP.46 „ext. funct. acc/dec time“ defines a time within the range of 0.00...20.00 s, which is required
for a change of the diameter signal of 0...100%.
7.15.8
Analog setting of parameter values
With this function it is possible to preset parameter values analog. The AUX-function or the motor-poti function
can be adjusted as source.
Analog parameter setting source (An.53)
This parameter determines whether the analog parameter setting occurs via the motor-poti or the aux-function.
An.53: Analog parameter setting source
Value
Function
0
AUX
1
Motorpoti function
The bus address of the parameter, that is to be adjusted in analog mode, is adjusted here (see chapter 11.1).
Following parameters can be adjusted.
Analog parameter setting destination (An.54)
uF.01 / 07
cn. 04 / 05 / 06
An.32 / 37 / 42 / 48
LE.00 / 01 / 02 / 03 / 04 / 05 / 06 / 07
cS.06 / 09 / 19 / 20 / 21 / 22 / 23
Ec.04 / 14
PS.31 / 33
Summary of Contents for COMBIVERT F5-A
Page 1: ...KEB COMBIVERT F5 A E H 4 4 APPLICATION MANUAL Mat No Rev 00F5AEA K440 1A...
Page 2: ...Page 1 1 2 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 4: ...Page 1 1 4 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 14: ...Page 1 1 14 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Page 20: ...Page 2 1 6 COMBIVERT F5 A E H KEB 2012 10 Product Overview...
Page 28: ...Page 3 1 8 COMBIVERT F5 A E H KEB 2012 10 Control Units...
Page 34: ...Page 4 1 6 COMBIVERT F5 A E H KEB 2012 10 Fundamentals...
Page 40: ...Page 4 2 6 COMBIVERT F5 A E H KEB 2012 10 Password input...
Page 42: ...Page 5 1 2 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Page 46: ...Page 5 1 6 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Page 70: ...Page 6 2 20 COMBIVERT F5 A E H KEB 2012 10 Start up...
Page 140: ...Page 7 3 44 COMBIVERT F5 A E H KEB 2012 10 Digital in and outputs...
Page 238: ...Page 7 7 12 COMBIVERT F5 A E H KEB 2012 10 Speed control...
Page 254: ...Page 7 8 16 COMBIVERT F5 A E H KEB 2012 10 Torque display and limiting...
Page 260: ...Page 7 9 6 COMBIVERT F5 A E H KEB 2012 10 Torque control...
Page 292: ...Page 7 11 26 COMBIVERT F5 A E H KEB 2012 10 Speed measurement...
Page 432: ...Page 7 14 14 COMBIVERT F5 A E H KEB 2012 10 Parameter sets...
Page 466: ...Page 7 15 34 COMBIVERT F5 A E H KEB 2012 10 Special functions...
Page 478: ...Page 7 16 12 COMBIVERT F5 A E H KEB 2012 10 CP Parameter definition...
Page 488: ...Page 8 1 10 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting...
Page 496: ...Page 9 1 8 COMBIVERT F5 A E H KEB 2012 10 General design...
Page 538: ...Page 11 1 28 COMBIVERT F5 A E H KEB 2012 10 Parameter...
Page 540: ...Page 12 1 2 COMBIVERT F5 A E H KEB 2008 02 Annex 12 1 1 Index 12 1 3...