5. Press the «Enter» key.
The display
Offset switches to 35.0°C.
The display
ADT ⇞ switches to 108°C.
The test mode is now activated.
6 . 1 b a r
0 8 : 1 5 A M
7 3 ° C
Header
9.1 TÜV inspection
Menu
Safety valve
: ☐
pRV:
16.0bar ¦ pi ⇞
0.0bar
Safety valve actuating pressure (FLUID)
Reset :
☐
·········
ADT ⇞
: ☑
Active line with check box
Offset
35.0°C ¦ ADT ⇞
108°C
6. Press the «ON» key.
The machine is running in LOAD.
The discharge temperature increases again.
The machine will switch off as soon as the discharge temperature attains a value of
110°C.
The machine does not shut down?
➤ Abort the test and contact an authorised service partner immediately.
Correct conclusion of the test
1. Press «Enter».
The setting mode is active.
The check box flashes in line
ADT ⇞.
2. Press the «DOWN» key.
The check box is deactivated.
3. Press «Enter».
The offset is reset to
0°C.
Result The test mode is de-activated and the test is completed.
Resetting
SIGMA CONTROL 2 will display the highest measured value if the test for switching off at exces‐
sive temperature is aborted.
Activate the
Reset check box in order to reset the stored value.
➤ Activate the
Reset check box.