3. Press «Enter».
The operating mode display flashes.
6 . 1 b a r
0 8 : 1 5 A M
8 0 ° C
Header
5.2.3 Load control
Menu
Local mode:
pB
Remote mode
: loc.-load RC
active line
------------------------------
▶1 pA/pB Clock
·········
pA/pB Cycle
4. Use «Up» or «Down» to set the
pB input.
5. Press «Enter».
The setting is applied.
6. Adjust the
pB nominal pressure, if necessary (see section 8.5).
The local operating mode
pB is set.
8.11.6.4 Activating the remote control
➤ Activate remote control see chapter 8.2.13.
Result SIGMA CONTROL 2 remote control is activated.
8.11.6.5 Assign an input for the LOAD remote contact for switching the pressure control
Precondition Access level 2 is activated.
1. Open the 5.2.3
<Configuration – Pressure control – Load control> menu.
2. Use «Up» or «Down» to select the
Load RC line.
3. Press «Enter».
The
DI display flashes.
6 . 1 b a r
0 8 : 1 5 A M
8 0 ° C
Header
5.2.3 Load control
Menu
pA/pB RC
DI1.05
☐
Logic :
+
pA/pB DO
DOR1.04
☐
Logic :
+
·········
Load RC
DI1.06
ok ☑
Active line
4. Use «Up» or «Down» to select the input for the LOAD remote contact.
5. Press «Enter».
The input for LOAD remote contact is assigned.
8
Initial Start-up
8.11 Setting the machine for master control operation
No.: 9_9450 12 E
User Manual Controller
SIGMA CONTROL 2 SCREW FLUID ≥5.0.X
145