8.8.1 Activating the heat recovery for machine type 2
The heat recovery can be set for local operation, as well as for remote operation. In remote opera‐
tion, the heat recovery can be controlled by means of a load remote contact.
Example: Heat recovery for machines in "remote operation".
Precondition Access level 2 is activated.
1. Open the 5.6
<Configuration – ETM> menu.
2. Use «Up» or «Down» to select the
Remote mode: line.
6 . 1 b a r
0 8 : 1 5 A M
8 0 ° C
Header
5.6 ETM
Menu
Heat recovery
Local mode:
inactive
Remote mode:
inactive
Active line
current
inactive
Status of heat recovery
3. Press the «DOWN» key.
4. Press «Enter».
The currently active operating mode flashes.
5. Use «Up» or «Down» key to set the
active option.
6. Press «Enter».
The setting is applied.
6 . 1 b a r
0 8 : 1 5 A M
8 0 ° C
Header
5.6 ETM
Menu
Heat recovery
Local mode:
inactive
Remote mode:
active
Active line
current
active
Status of heat recovery
7. If a load remote contact controls the remote control, set the
remote contact option.
6 . 1 b a r
0 8 : 1 5 A M
8 0 ° C
Header
5.6 ETM
Menu
Remote mode:
remote contact
current
active
Status of heat recovery
------------------------------
RC
DI1.07
ok
☑
Active line
Key remote
: ☑
8
Initial Start-up
8.8
Electronic Thermal Management
No.: 9_9450 12 E
User Manual Controller
SIGMA CONTROL 2 SCREW FLUID ≥5.0.X