Message
Meaning
0202 O
IOSlot3 Undervoltage error %d
The internal voltage monitoring reports undervoltage fault
IOSlot3
0300 O
Cycle-exact data recording active
Service information
0301 O
SD card defective!
Service information
0500 O
Safety shutdown "IOMDiagnosis()"
Service information
0501 O
Safety shutdown "Safeguard()"
Service information
0550 O
ADT channel error "currleak" detected
Short-term overload fault without shut-down occurred at
ADT.
0551 O
ADT channel error "channel open"
detected
Short-term overload fault without shut-down occurred at
ADT.
0850 O
IOSlot%d - bus error
Short-term IOM bus fault without shut-down has occurred
0867 O
AII%d.0%d - overload fault
Short-term overload fault without shut-down occurred at
All.
0873 O
AII%d.0%d - overload fault
Short-term overload fault without shut-down occurred at
All.
0879 O
AII%d.0%d - overload fault
Short-term overload fault without shut-down occurred at
All.
0885 O
AII%d.0%d - overload fault
Short-term overload fault without shut-down occurred at
All.
1000 O
2 RFID Equipment Cards successfully
registered
You successfully registered 2 RFID Equipment Cards at
the controller.
1018 O
IOSlot%d - bus error
Short-term IOM bus fault without shut-down has occurred
1035 O
AII%d.0%d - overload fault
Short-term overload fault without shut-down occurred at
All.
1041 O
AII%d.0%d - overload fault
Short-term overload fault without shut-down occurred at
All.
1047 O
AII%d.0%d - overload fault
Short-term overload fault without shut-down occurred at
All.
1053 O
AII%d.0%d - overload fault
Short-term overload fault without shut-down occurred at
All.
1186 O
IOSlot%d - bus error
Short-term IOM bus fault without shut-down has occurred
10 Fault Recognition and Rectification
10.4 Interpreting operating messages
No.: 9_9450 12 E
User Manual Controller
SIGMA CONTROL 2 SCREW FLUID ≥5.0.X
229