1. Open the menu 3.1
<Operating data – Operating hours>.
6 . 1 b a r
0 8 : 1 5 A M
8 0 ° C
Header
3.1 Operating hours
Menu
Compressor
3050h
active line
On load
3030h
Motor
3050h
Compressor block
3050h
SIGMA CONTROL 2
3050h
2. Using the «Up» or «Down» key, select the line
Compressor block.
3. Press «Enter».
The runtime display flashes.
6 . 1 b a r
0 8 : 1 5 A M
8 0 ° C
Header
3.1 Operating hours
Menu
Compressor
3050h
On load
3030h
Motor
3050h
Compressor block
0h
active line
SIGMA CONTROL 2
3050h
4. Use «Down» or «Up» key to set the value for operating hours to zero.
5. Press «Enter».
The setting is applied accordingly.
6. Press «Escape» repeatedly to leave this menu.
Result The operating hours for the new airend are set to
0 h.
9.8.2 Checking the switching cycles
The system monitors the usage times of safety-relevant components to ensure the proper
condition of all safety-relevant functions. Depending on the component, the usage time may
be defined by run time or switching cycles. For the mains contactor, the usage time is defined
by the maximum permissible number of switching cycles.
The mains contactor switching cycle counter in SIGMA CONTROL 2 records the number of
switching cycles and generates a warning message when the maximum permissible number
of switching cycles is exceeded.
When this warning message is generated, the safety-relevant function is no longer ensured.
The mains contactor must be replaced!
➤ Follow all instructions carefully.
Displaying switching cycles
Precondition Access level 2 is activated
1. Open the 3.2
<Operating data – Switching cycles> menu.
9
Operation
9.8
Displaying operating data
No.: 9_9450 12 E
User Manual Controller
SIGMA CONTROL 2 SCREW FLUID ≥5.0.X
185