QFX10000 AC Power Supply LEDs
The QFX10000-PWR-AC power supply has four LEDs on its faceplate: INP1, INP2, PWR OK, and
FAULT. These LEDs display information about the status of the power supply. See
Figure 31: LEDs on a QFX10000-PWR-AC, Power Supply in QFX10000 Switches
1
—
FAULT
3
—
INP2–Source input 2
2
—
PWR OK
4
—
INP1–Source input 1
describes the LEDs on a QFX10000-AC power supply in QFX10008 and
QFX10016 modular chassis.
Table 21: LEDs on a QFX10000-AC Power Supply in a QFX10000
LED
Color
State
Description
INP1 (INP0 in CLI output)
or INP2 (INP1 in CLI
output)
Yellow
Blinking
Indicates that the AC power input voltage is not
within normal operating range.
Green
Solid
AC is within operating range (200–240 VAC).
64
Summary of Contents for QFX10016
Page 1: ...QFX10016 Switch Hardware Guide Published 2022 09 09...
Page 10: ...Compliance Statements for Environmental Requirements 428 x...
Page 15: ...Figure 1 on page 5 shows a front and rear view of the QFX10016 4...
Page 16: ...Figure 1 QFX10016 Front and Rear 5...
Page 239: ...RELATED DOCUMENTATION QFX10008 Installation Overview QFX10002 System Overview 228...
Page 270: ...1 ESD point Figure 113 ESD Point on QFX10016 Chassis Rear 1 ESD point 259...
Page 287: ...Figure 130 Installing a JNP10K PWR AC2 in a QFX10016 276...
Page 322: ...Figure 159 Installing a JNP10K PWR DC2 in QFX10016 311...
Page 366: ...5 CHAPTER Troubleshooting Troubleshooting QFX10000 Modular Chassis 356...