Overview
The line cards in QFX10000 modular switches combine a Packet Forwarding Engine and Ethernet
interfaces in a single assembly. Line cards are field-replaceable units (FRUs) that can be installed in the
line card slots on the front of the switch chassis. The line cards are hot-insertable and hot-removable;
you can remove and replace them without powering off the switch or disrupting switch functions. See
Figure 52: QFX10000-36Q Port Panel
1
—
Status and activity LEDs
2
—
Network ports
Each QSFP28 socket can be configured to support:
• 100-Gigabit Ethernet using QSFP28 optical transceivers. When a QSFP28 transceiver is inserted into
the ports marked with a fine black line underneath the socket and the port is configured for 100-
Gigabit Ethernet, the two adjacent ports are disabled and the QSFP28 socket is enabled for 100-
Gigabit Ethernet.
• 40-Gigabit Ethernet using QSFP+ optical transceivers.
• 10-Gigabit Ethernet using breakout cabling and attached optical transceivers. When configured for
channelization, the system converts the 40-Gigabit Ethernet port into 4 independent 10-Gigabit
Ethernet ports.
Any of the 36 ports 0 through 35 can be configured as either uplink or access ports.
Switch Ports
Each of the 12 QSFP28 ports supports:
• 100-Gigabit Ethernet QSFP28 transceivers
• 40-Gigabit Ethernet QSFP+ transceivers
• QSFP28 direct attach copper (DAC) cables
• QSFP+ DAC cables
105
Summary of Contents for QFX10016
Page 1: ...QFX10016 Switch Hardware Guide Published 2022 09 09...
Page 10: ...Compliance Statements for Environmental Requirements 428 x...
Page 15: ...Figure 1 on page 5 shows a front and rear view of the QFX10016 4...
Page 16: ...Figure 1 QFX10016 Front and Rear 5...
Page 239: ...RELATED DOCUMENTATION QFX10008 Installation Overview QFX10002 System Overview 228...
Page 270: ...1 ESD point Figure 113 ESD Point on QFX10016 Chassis Rear 1 ESD point 259...
Page 287: ...Figure 130 Installing a JNP10K PWR AC2 in a QFX10016 276...
Page 322: ...Figure 159 Installing a JNP10K PWR DC2 in QFX10016 311...
Page 366: ...5 CHAPTER Troubleshooting Troubleshooting QFX10000 Modular Chassis 356...