Table 21: LEDs on a QFX10000-AC Power Supply in a QFX10000
(Continued)
LED
Color
State
Description
Dark
Unlit
The power supply is switched off.
PWR OK
Green
Solid
DC power output is within normal operating
range.
Yellow
Blinking
The output is out of the limits.
FAULT
Dark
Unlit
Power supply is functioning normally.
Red
Solid
Power supply has failed and must be replaced. Or,
only one input is powered and the enabled switch
for the input that is not powered is set to ON. See
Connect AC Power to a QFX Modular Chassis
for
more information about the enable switches.
NOTE: If the INP1 or INP2 LED and the PWR OK LED are unlit, the AC power cord is not
installed properly or the power supply has failed.
If the INP1 or INP2 LED is lit and the PWR OK LED is unlit, the AC power supply is not installed
properly or the power supply has an internal failure.
SEE ALSO
Power Requirements for QFX10000 Components
65
Summary of Contents for QFX10016
Page 1: ...QFX10016 Switch Hardware Guide Published 2022 09 09...
Page 10: ...Compliance Statements for Environmental Requirements 428 x...
Page 15: ...Figure 1 on page 5 shows a front and rear view of the QFX10016 4...
Page 16: ...Figure 1 QFX10016 Front and Rear 5...
Page 239: ...RELATED DOCUMENTATION QFX10008 Installation Overview QFX10002 System Overview 228...
Page 270: ...1 ESD point Figure 113 ESD Point on QFX10016 Chassis Rear 1 ESD point 259...
Page 287: ...Figure 130 Installing a JNP10K PWR AC2 in a QFX10016 276...
Page 322: ...Figure 159 Installing a JNP10K PWR DC2 in QFX10016 311...
Page 366: ...5 CHAPTER Troubleshooting Troubleshooting QFX10000 Modular Chassis 356...