Table 83: Chassis Component Alarm Conditions on QFX10000 Modular Models
(Continued)
Chassis
Component
Alarm Condition
Alarm
Severity
Remedy
A power supply output has
failed.
Major (red)
Check power supply output connection.
A power supply has failed.
Major (red)
Replace the failed power supply.
AC and DC power supplies are
installed.
Major (red)
Do not mix AC and DC power supplies.
Inadequate number of power
supplies.
Major (red)
Install an additional power supply.
Temperature
The chassis temperature has
exceeded 131° F (55° C), the
fans have been turned on to full
speed, and one or more fans
have failed.
Minor
(yellow)
•
Check room temperature.
•
Check airflow.
•
Replace the fan tray.
The chassis temperature has
exceeded 149° F (65° C), and
the fans have been turned on to
full speed.
Minor
(yellow)
•
Check room temperature.
•
Check airflow.
•
Check the fans.
The chassis temperature has
exceeded 149° F (65° C), and a
fan has failed. If this condition
persists for more than 4
minutes, the switch will shut
down.
Major (red)
•
Check room temperature.
•
Check airflow.
•
Check the fan.
Chassis temperature has
exceeded 167° F (75° C). If this
condition persists for more than
4 minutes, the switch will shut
down.
Major (red)
•
Check room temperature.
•
Check airflow.
•
Check fan.
360
Summary of Contents for QFX10016
Page 1: ...QFX10016 Switch Hardware Guide Published 2022 09 09...
Page 10: ...Compliance Statements for Environmental Requirements 428 x...
Page 15: ...Figure 1 on page 5 shows a front and rear view of the QFX10016 4...
Page 16: ...Figure 1 QFX10016 Front and Rear 5...
Page 239: ...RELATED DOCUMENTATION QFX10008 Installation Overview QFX10002 System Overview 228...
Page 270: ...1 ESD point Figure 113 ESD Point on QFX10016 Chassis Rear 1 ESD point 259...
Page 287: ...Figure 130 Installing a JNP10K PWR AC2 in a QFX10016 276...
Page 322: ...Figure 159 Installing a JNP10K PWR DC2 in QFX10016 311...
Page 366: ...5 CHAPTER Troubleshooting Troubleshooting QFX10000 Modular Chassis 356...