3. Insert the cable connector into the optical transceiver (see
Figure 197: Connect a Fiber-Optic Cable to an Optical Transceiver Installed in a Device
g000704
Transceiver
Fiber-optic
cable
4. Secure the cables so that they do not support their own weight. Place excess cable out of the way in
a neatly coiled loop. Placing fasteners on a loop helps cables maintain their shape.
CAUTION: Do not bend fiber-optic cables beyond their minimum bend radius. An arc
smaller than a few inches in diameter can damage the cables and cause problems that
are difficult to diagnose.
Do not let fiber-optic cables hang free from the connector. Do not allow fastened
loops of cables to dangle, which stresses the cables at the fastening point.
How to Handle Fiber-Optic Cables
Fiber-optic cables connect to optical transceivers that are installed in Juniper Networks devices.
Follow these guidelines when handling fiber-optic cables:
• When you unplug a fiber-optic cable from a transceiver, place rubber safety caps over the transceiver
and on the end of the cable.
• Anchor fiber-optic cables to prevent stress on the connectors. When attaching a fiber-optic cable to
a transceiver, be sure to secure the fiber-optic cable so that it does not support its own weight as it
hangs to the floor. Never let a fiber-optic cable hang free from the connector.
• Avoid bending fiber-optic cables beyond their minimum bend radius. Bending fiber-optic cables into
arcs smaller than a few inches in diameter can damage the cables and cause problems that are
difficult to diagnose.
• Frequent plugging and unplugging of fiber-optic cables in and out of optical instruments can damage
the instruments, which are expensive to repair. To prevent damage from overuse, attach a short fiber
348
Summary of Contents for QFX10016
Page 1: ...QFX10016 Switch Hardware Guide Published 2022 09 09...
Page 10: ...Compliance Statements for Environmental Requirements 428 x...
Page 15: ...Figure 1 on page 5 shows a front and rear view of the QFX10016 4...
Page 16: ...Figure 1 QFX10016 Front and Rear 5...
Page 239: ...RELATED DOCUMENTATION QFX10008 Installation Overview QFX10002 System Overview 228...
Page 270: ...1 ESD point Figure 113 ESD Point on QFX10016 Chassis Rear 1 ESD point 259...
Page 287: ...Figure 130 Installing a JNP10K PWR AC2 in a QFX10016 276...
Page 322: ...Figure 159 Installing a JNP10K PWR DC2 in QFX10016 311...
Page 366: ...5 CHAPTER Troubleshooting Troubleshooting QFX10000 Modular Chassis 356...