![Icom D-STAR ID-4100A Advanced Manual Download Page 142](http://html1.mh-extra.com/html/icom/d-star-id-4100a/d-star-id-4100a_advanced-manual_611923142.webp)
8
REPEATER AND DUPLEX OPERATIONS
8-4
The Duplex operation shifts the transmit frequency
up or down from the receive frequency by an offset
amount.
D
Setting the frequency offset
NOTE:
The frequency offset cannot be changed
when using the DR function.
DUP/TONE... >
Offset Freq
1. Push [MENU].
2. Rotate [DIAL] to select “DUP/TONE...,” then push
[
ï
].
3. Select “Offset Freq,” then push [
ï
].
4. Rotate [DIAL] to set the offset.
(Example: 0.700.00 MHz)
L
Set to between 0.000.00 and 59.99500 MHz.
L
The selected tuning step in the VFO mode is used to
set the offset.
5. Push [
ï
] to set the offset.
6. Push [MENU].
• Returns to the standby screen.
D
Setting the duplex direction
1. Push [QUICK].
2. Rotate [DIAL] to select “DUP,” then push [
ï
].
3. Select the offset direction, then push [
ï
].
•OFF: For simplex operation (the receive and
transmit frequencies are the same).
•DUP–: The transmit frequency shifts down
from the receive frequency by the offset
amount.
•DUP+: The transmit frequency shifts up from the
receive frequency by the offset amount.
•Displays “D–” or “D+.”
Duplex operation
TIP:
If the offset value will cause the transmit
frequency to be out of the band, “OFF BAND” is
displayed on the display when [PTT] is pushed, and
transmit will be inhibited. (p. 8-5)
D
Duplex operation
1. Push [MONI] to listen to the transmit frequency to
check whether another station is transmitting on
it, or not.
• The transceiver transmit frequency is displayed on the
display.
2. Push [MONI] again to cancel monitoring.
3. Operate in the normal way.
NOTE:
When the Auto repeater is ON, and the
operating frequency is set out of the repeater output
frequency range, the duplex mode is automatically
cancelled.
Previous view