v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Error
message
Action
Unknown
SERR/PERR
detected
on
PCI
bus
Chassis#=X
Slot#=Y
Bus#=Z
Dev.ID=0xSSSS
Vend.ID=0xTTTT
Status=0xUUUU
DevFun#=0xVV
1.
If
the
slot
number
is
greater
than
0,
complete
the
following
steps:
a.
Reseat
the
adapter.
b.
Replace
the
adapter.
2.
If
the
slot
number
is
0,
replace
the
PCI
board.
Address
of
special
cycle
DPE
on
PCI
primary
Chassis#=X
Slot#=Y
Bus#=Z
Dev.ID=0xSSSS
Vend.ID=0xTTTT
Status=0xUUUU
DevFun#=0xVV
1.
If
the
slot
number
is
greater
than
0,
complete
the
following
steps:
a.
Reseat
the
adapter.
b.
Replace
the
adapter.
2.
If
the
slot
number
is
0,
replace
the
PCI
board.
Master
read
parity
error
on
PCI
primary
Chassis#=4
Slot#=2
Bus#=3
Dev.ID=0xaa99
Vend.ID=0xccbb
Status=0xeedd
DevFun#=0xff
1.
If
the
slot
number
is
greater
than
0,
complete
the
following
steps:
a.
Reseat
the
adapter.
b.
Replace
the
adapter.
2.
If
the
slot
number
is
0,
replace
the
PCI
board.
Received
target
parity
error
on
PCI
primary
Chassis#=X
Slot#=Y
Bus#=Z
Dev.ID=0xSSSS
Vend.ID=0xTTTT
Status=0xUUUU
DevFun#=0xVV
1.
If
the
slot
number
is
greater
than
0,
complete
the
following
steps:
a.
Reseat
the
adapter.
b.
Replace
the
adapter.
2.
If
the
slot
number
is
0,
replace
the
PCI
board.
Master
write
parity
error
on
PCI
primary
Chassis#=X
Slot#=Y
Bus#=Z
Dev.ID=0xSSSS
Vend.ID=0xTTTT
Status=0xUUUU
DevFun#=0xVV
1.
If
the
slot
number
is
greater
than
0,
complete
the
following
steps:
a.
Reseat
the
adapter.
b.
Replace
the
adapter.
2.
If
the
slot
number
is
0,
replace
the
PCI
board.
Device
signaled
SERR
on
PCI
primary.
Chassis#=X
Slot#=Y
Bus#=Z
Dev.ID=0xSSSS
Vend.ID=0xTTTT
Status=0xUUUU
DevFun#=0xVV
1.
If
the
slot
number
is
greater
than
0,
complete
the
following
steps:
a.
Reseat
the
adapter.
b.
Replace
the
adapter.
2.
If
the
slot
number
is
0,
replace
the
PCI
board.
Slave
signaled
parity
error
on
PCI
primary
Chassis#=X
Slot#=Y
Bus#=Z
Dev.ID=0xSSSS
Vend.ID=0xTTTT
Status=0xUUUU
DevFun#=0xVV
1.
If
the
slot
number
is
greater
than
0,
complete
the
following
steps:
a.
Reseat
the
adapter.
b.
Replace
the
adapter.
2.
If
the
slot
number
is
0,
replace
the
PCI
board.
Signaled
target
abort
on
PCI
primary
Chassis#=X
Slot#=Y
Bus#=Z
Dev.ID=0xSSSS
Vend.ID=0xTTTT
Status=0xUUUU
DevFun#=0xVV
1.
If
the
slot
number
is
greater
than
0,
complete
the
following
steps:
a.
Reseat
the
adapter.
b.
Replace
the
adapter.
2.
If
the
slot
number
is
0,
replace
the
PCI
board.
94
IBM
System
x3950
Type
8878
and
System
x3950
E
Type
8879:
Problem
Determination
and
Service
Guide