v
A
new
error
occurs,
causing
the
system-error
LED
to
be
lit
again.
Light
path
diagnostic
LEDs
The
following
table
describes
the
LEDs
on
the
light
path
diagnostics
panel
and
suggested
actions
to
correct
the
detected
problems.
v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Lit
light
path
diagnostics
LED
with
the
system-error
or
system-information
LED
also
lit
Description
Action
All
LEDs
off
(the
power
LED
is
lit).
No
action
necessary.
OVERSPEC
There
is
insufficient
power
to
power
the
system.
The
NON
RED
and
LOG
LEDs
might
also
be
lit.
1.
Add
an
optional
power
supply
if
only
one
power
supply
is
installed.
2.
Use
220
V
ac
instead
of
110
V
ac.
3.
Reseat
the
following
components:
a.
Power
supply
b.
(Trained
service
technician
only)
Power
backplane
4.
Remove
optional
devices.
5.
Replace
the
components
listed
in
step
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
PS
A
power
supply
has
failed
or
has
been
removed;
also
see
Note:
In
a
redundant
power
configuration,
the
dc
power
LED
on
one
power
supply
might
be
off.
1.
Reinstall
the
removed
power
supply.
2.
Check
the
individual
power-supply
LEDs
to
find
the
failing
power
supply.
3.
Reseat
the
following
components:
a.
Failing
power
supply
b.
(Trained
service
technician
only)
Power
backplane
4.
Replace
the
components
listed
in
step
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
5.
If
a
12
V
fault
has
occurred,
ac
power
must
be
removed
before
dc
power
can
be
restored.
LINK
There
is
a
fault
in
an
SMP
Expansion
Port
or
SMP
Expansion
cable.
Note:
The
SMP
Expansion
Port
link
LED
on
the
failed
port
is
off.
1.
Check
the
SMP
Expansion
Port
link
LEDs
to
find
the
failing
port
or
cable.
2.
Reseat
the
SMP
Expansion
cables.
3.
Replace
the
SMP
Expansion
cables.
4.
(Trained
service
technician
only)
Replace
the
scalability
cartridge
assembly.
If
the
scalability
cartridge
assembly
must
be
replaced,
call
for
service.
Chapter
2.
Diagnostics
53