v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Error
code
Description
Action
162
Device
configuration
error.
1.
Run
the
Configuration/Setup
Utility
program,
select
Load
Default
Settings
,
and
save
the
settings.
2.
Reseat
the
following
components:
a.
Battery
b.
Failing
device
c.
I/O
board
3.
Remove
the
battery
for
60
minutes;
then,
reinstall
the
battery
and
restart
the
server.
4.
Replace
the
components
listed
in
step
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
163
Real-time
clock
error.
1.
Run
the
Configuration/Setup
Utility
program,
select
Load
Default
Settings
,
make
sure
that
the
date
and
time
are
correct,
and
save
the
settings.
2.
Reseat
the
following
components:
a.
Battery
b.
I/O
board
3.
Replace
the
components
listed
in
step
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
175
Bad
EEPROM
CRC#1.
1.
Restart
the
server.
2.
Update
the
BMC
firmware
(see
3.
Reseat
the
microprocessor
tray.
4.
(Trained
service
technician
only)
Replace
the
microprocessor
tray.
178
System
VPD
not
available.
1.
Restart
the
server.
2.
Update
the
BMC
firmware
(see
3.
Reseat
the
microprocessor
tray.
4.
(Trained
service
technician
only)
Replace
the
microprocessor
tray.
22
IBM
System
x3950
Type
8878
and
System
x3950
E
Type
8879:
Problem
Determination
and
Service
Guide