000
The
server
passed
the
test.
Do
not
replace
a
CRU
or
FRU.
195
The
Esc
key
was
pressed
to
end
the
test.
Do
not
replace
a
CRU
or
FRU.
197
This
is
a
warning
error,
but
it
does
not
indicate
a
hardware
failure;
do
not
replace
a
CRU
or
FRU.
Take
the
action
that
is
indicated
in
the
Action
column
but
do
not
replace
a
CRU
or
a
FRU
.
See
the
description
of
Warning
in
for
more
information.
v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Error
code
Description
Action
001-198-000
Test
aborted.
1.
Check
the
system-error
log
and
the
BMC
log
for
messages
indicating
the
cause
of
the
error,
and
take
the
indicated
action.
2.
From
the
diagnostic
programs,
run
Quick
Memory
Test
All
Banks;
then,
if
an
error
is
detected,
take
the
indicated
action.
3.
Reinstall
and,
if
necessary,
update
the
BIOS
code
on
the
server;
then,
rerun
the
test
(see
001-250-00x
Test
failed,
where
v
x
of
0
=
ECC
logic
on
I/O
board
v
x
of
1
=
ECC
logic
on
memory
card
1.
Check
the
system-error
log
and
the
BMC
log
for
messages
indicating
the
cause
of
the
error,
and
take
the
indicated
action.
2.
From
the
diagnostic
programs,
run
Quick
Memory
Test
All
Banks;
then,
if
an
error
is
detected,
take
the
indicated
action.
Make
sure
you
re-enable
the
memory
in
the
Configuration/Setup
Utility
program.
See,
3.
From
the
diagnostic
programs,
rerun
the
ECC
test;
then,
if
an
error
is
detected,
take
the
indicated
action.
4.
Reseat
the
following
components:
a.
Memory
card
b.
I/O
board
5.
Replace
the
components
listed
in
step
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
Make
sure
you
re-enable
the
memory
in
the
Configuration/Setup
Utility
program.
See,
001-292-000
Core
system:
failed/CMOS
checksum
failed.
Load
the
BIOS
default
settings
using
the
Configuration/Setup
Utility
program
and
run
the
test
again
(see
001-xxx-000
Failed
core
tests.
1.
Reseat
the
I/O
board.
2.
Replace
the
I/O
board.
001-xxx-001
Failed
core
tests.
1.
Reseat
the
I/O
board.
2.
Replace
the
I/O
board.
62
IBM
System
x3950
Type
8878
and
System
x3950
E
Type
8879:
Problem
Determination
and
Service
Guide