Error
code
Description
Action
180-xxx-005
Failed
SCSI
backplane
LED
test.
1.
Reseat
the
following
components:
a.
SAS
hard
disk
drive
backplane
cable
b.
I/O
board
c.
Microprocessor
tray
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
a.
SAS
hard
disk
drive
backplane
cable
b.
SAS
hard
disk
drive
backplane
c.
I/O
board
d.
(Trained
service
technician
only)
Microprocessor
tray
180-xxx-006
Failed
memory
card
LED
test.
1.
Reseat
the
following
components:
a.
Memory
card
b.
Microprocessor
tray
c.
I/O
board
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
a.
Memory
card
b.
(Trained
service
technician
only)
Microprocessor
tray
c.
I/O
board
180-xxx-007
Failed
power
supply
fan
LED
test.
1.
Reseat
the
following
components:
a.
Power
supply
b.
(Trained
service
technician
only)
Power
supply
structure
c.
I/O
board
2.
Replace
the
components
listed
in
step
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
180-xxx-008
Failed
I/O
board
LED
test.
1.
Reseat
the
I/O
board.
2.
Replace
the
I/O
board.
180-xxx-009
Failed
Active
™
PCI
LED
test.
1.
Reseat
the
following
components:
a.
(Trained
service
technician
only)
PCI-X
switch
card
assembly
b.
I/O
board
2.
Replace
the
components
listed
in
step
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
Chapter
2.
Diagnostics
75