v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Error
code
Description
Action
01295085
ECC
checking
hardware
test
error.
1.
Reseat
the
following
components:
a.
(Trained
service
technician
only)
Microprocessor
b.
DIMM
c.
Microprocessor
tray
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
a.
(Trained
service
technician
only)
Microprocessor
b.
DIMM
c.
(Trained
service
technician
only)
Microprocessor
tray
01298001
No
update
data
for
processor
1.
1.
Make
sure
that
all
microprocessors
have
the
same
cache
size
(see
2.
Update
the
BIOS
code
again
(see
3.
(Trained
service
technician
only)
Reseat
microprocessor
1.
4.
(Trained
service
technician
only)
Replace
microprocessor
1.
01298002
No
update
data
for
processor
2.
1.
Make
sure
that
all
microprocessors
have
the
same
cache
size
(see
2.
Update
the
BIOS
code
again
(see
3.
(Trained
service
technician
only)
Reseat
microprocessor
2.
4.
(Trained
service
technician
only)
Replace
microprocessor
2.
01298004
No
update
data
for
processor
3.
1.
Make
sure
that
all
microprocessors
have
the
same
cache
size
(see
2.
Update
the
BIOS
code
again
(see
3.
(Trained
service
technician
only)
Reseat
microprocessor
3.
4.
(Trained
service
technician
only)
Replace
microprocessor
3.
32
IBM
System
x3950
Type
8878
and
System
x3950
E
Type
8879:
Problem
Determination
and
Service
Guide