Error
message
Action
PCI
to
PCI
Bridge
Discard
Timer
Error
Chassis#=X
Slot#=Y
Bus#=Z
Dev.ID=0xSSSS
Vend.ID=0xTTTT
Status=0xUUUU
DevFun#=0xVV
1.
If
the
slot
number
is
greater
than
0,
complete
the
following
steps:
a.
Reseat
the
adapter.
b.
Replace
the
adapter.
2.
If
the
slot
number
is
0,
replace
the
PCI
board.
SMI
handler
reporting
Memory
Mirroring
Failover
Occurred.
Running
from
mirrored
image.
Note:
This
message
immediately
follows
an
uncorrectable
memory
error.
1.
Reseat
the
DIMM
or
memory
card.
2.
If
the
DIMM
was
disabled
by
the
user,
run
the
Configuration/Setup
Utility
program
and
enable
the
DIMM.
3.
Replace
the
DIMM
or
memory
card.
4.
If
the
DIMM
was
disabled
by
the
user,
run
the
Configuration/Setup
Utility
program
and
enable
the
DIMM.
SMI
handler
reporting
Processor
Event:
Unrecoverable
error.
Chassis
Number
=
X.
Processor
ID
=
Y.
(Trained
service
technician
only)
Replace
the
microprocessor.
Solving
SCSI
problems
Note:
This
information
also
applies
to
Serial
Attached
SCSI
(SAS)
problems.
For
any
SCSI
error
message,
one
or
more
of
the
following
devices
might
be
causing
the
problem:
v
A
failing
SCSI
device
(adapter,
drive,
or
controller)
v
An
incorrect
SCSI
termination
jumper
setting
v
Duplicate
SCSI
IDs
in
the
same
SCSI
chain
v
A
missing
or
incorrectly
installed
SCSI
terminator
v
A
defective
SCSI
terminator
v
An
incorrectly
installed
cable
v
A
defective
cable
For
any
SCSI
error
message,
follow
these
suggested
actions
in
the
order
in
which
they
are
listed
until
the
problem
is
solved:
1.
Make
sure
that
external
SCSI
devices
are
turned
on
before
you
turn
on
the
server.
2.
Make
sure
that
the
cables
for
all
external
SCSI
devices
are
connected
correctly.
3.
If
an
external
SCSI
device
is
attached,
make
sure
that
the
external
SCSI
termination
is
set
to
automatic.
4.
Make
sure
that
the
last
device
in
each
SCSI
chain
is
terminated
correctly.
5.
Make
sure
that
the
SCSI
devices
are
configured
correctly.
104
IBM
System
x3950
Type
8878
and
System
x3950
E
Type
8879:
Problem
Determination
and
Service
Guide