v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Lit
light
path
diagnostics
LED
with
the
system-error
or
system-information
LED
also
lit
Description
Action
MEM
Memory
failure.
Note:
The
error
LED
on
the
memory
card
is
also
lit.
1.
Remove
the
memory
card
with
the
lit
error
LED
on
the
top
of
the
card;
then,
press
the
light
path
button
on
the
memory
card
to
identify
the
failed
card
or
DIMM.
2.
Reseat
the
DIMM.
3.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
and
re-enabling
the
memory
each
time:
a.
Memory
card
b.
DIMM
c.
(Trained
service
technician
only)
Microprocessor
tray
NMI
A
hardware
error
has
been
reported
to
the
operating
system.
Note:
The
PCI
or
MEM
LED
might
also
be
lit.
1.
See
the
BMC
log
and
the
system-error
log
(see
2.
If
the
PCI
LED
is
lit,
follow
the
instructions
for
that
LED.
3.
If
the
MEM
LED
is
lit,
follow
the
instructions
for
that
LED.
4.
Restart
the
server.
PCI
A
PCI
adapter
has
failed.
Note:
The
error
LED
next
to
the
failing
adapter
on
the
PCI-X
board
is
also
lit.
1.
See
the
BMC
log
or
the
system-error
log
(see
2.
Reseat
the
following
components:
a.
Failing
adapter
b.
I/O
board
3.
Replace
the
components
listed
in
step
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
SP
There
is
a
fault
in
the
Remote
Supervisor
Adapter
II
SlimLine.
1.
Reseat
the
Remote
Supervisor
Adapter
II
SlimLine.
2.
Update
the
firmware
for
the
Remote
Supervisor
Adapter
II
SlimLine
(see
3.
Replace
the
Remote
Supervisor
Adapter
II
SlimLine.
Chapter
2.
Diagnostics
55