v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Error
code
Description
Action
1602
Systems-management
adapter
communication
error.
1.
Make
sure
that
the
Remote
Supervisor
Adapter
II
SlimLine
is
installed
correctly.
2.
Update
the
Remote
Supervisor
Adapter
II
SlimLine
firmware
(see
3.
Update
the
BMC
firmware
(see
4.
Reseat
the
following
components:
a.
Microprocessor
tray
b.
I/O
board
c.
(Trained
service
technician
only)
PCI-X
board
5.
Replace
the
Remote
Supervisor
Adapter
II
SlimLine.
6.
(Trained
service
technician
only)
Replace
the
microprocessor
tray.
1762
Fixed
disk
configuration
error.
1.
Run
the
Configuration/Setup
Utility
program
and
load
the
defaults.
2.
Reseat
the
following
components:
a.
SAS
cables
b.
SAS
hard
disk
drive
c.
I/O
board
3.
Replace
the
components
listed
in
step
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
178x
Fixed
disk
error.
1.
Reseat
the
hard
disk
drive
cables.
2.
Replace
the
hard
disk
drive
cables.
3.
Run
the
hard
disk
drive
diagnostic
tests.
4.
Reseat
the
following
components:
a.
Optional
ServeRAID
™
-8i
adapter.
b.
Hard
disk
drive.
c.
I/O
board.
5.
Replace
the
components
listed
in
step
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
1800
Unavailable
PCI
hardware
interrupt.
1.
Run
the
Configuration/Setup
Utility
program
and
adjust
the
adapter
settings.
2.
Remove
each
adapter
one
at
a
time,
restarting
the
server
each
time,
until
the
problem
is
isolated.
Chapter
2.
Diagnostics
25