v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Error
code
Description
Action
166-201-005
ISMP
indicates
I2C
errors
on
bus
S.
1.
Reseat
the
following
components:
a.
SAS
hard
disk
drive
backplane
cables
b.
I/O
board
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
a.
SAS
hard
disk
drive
backplane
b.
I/O
board
166-201-006
ISMP
indicates
I2C
errors
on
bus
O.
1.
Reseat
the
following
components:
a.
(Trained
service
technician
only)
Operator
information
panel
b.
I/O
board
2.
Replace
the
components
listed
in
step
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
166-201-007
ISMP
indicates
I2C
errors
on
bus
M0.
1.
Reseat
the
following
components:
a.
Memory
card
b.
I/O
board
c.
Microprocessor
tray
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
a.
Memory
card
b.
I/O
board
c.
(Trained
service
technician
only)
Microprocessor
tray
166-201-008
ISMP
indicates
I2C
errors
on
bus
M1.
1.
Reseat
the
following
components:
a.
Memory
card
b.
I/O
board
c.
Microprocessor
tray
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
a.
Memory
card
b.
I/O
board
c.
(Trained
service
technician
only)
Microprocessor
tray
72
IBM
System
x3950
Type
8878
and
System
x3950
E
Type
8879:
Problem
Determination
and
Service
Guide