v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
System-error
log
message
Action
OS
Watchdog
Triggered
1.
Reconfigure
the
O/S
watchdog
timer
to
be
a
higher
value.
2.
Reinstall
the
Remote
Supervisor
Adapter
II
SlimLine
device
driver
for
the
operating
system.
3.
Disable
the
O/S
watchdog.
4.
Check
the
integrity
of
the
installed
operating
system.
5.
Reinstall
the
operating
system
with
applicable
device
drivers.
PCI-X
Card
Power
Good
Fault
1.
Reseat
the
Remote
Supervisor
Adapter
II
SlimLine,
if
one
is
present.
2.
Reseat
the
I/O
board.
3.
Replace
the
I/O
board.
4.
(Trained
service
technician
only)
Replace
the
PCI-X
board.
POST
Watchdog
Triggered
1.
Reconfigure
the
POST
watchdog
timer
to
be
a
higher
value
(consistent
with
the
time
it
takes
to
complete
POST).
2.
Disable
the
POST
watchdog.
Power
Good
Fault
detected
by
memory
card
%d.
1.
Reseat
the
memory
cards.
2.
Reseat
the
DIMMs.
3.
Reseat
the
microprocessor
tray.
4.
(Trained
service
technician
only)
Replace
the
power
backplane.
5.
(Trained
service
technician
only)
Replace
the
microprocessor
tray.
Power
Supply
%d
Temperature
Warning
1.
Make
sure
that
the
power
supply
fans
have
good
airflow
and
are
not
obstructed.
2.
Make
sure
the
room
temperature
is
within
the
recommended
range
(see
“Environment”
at
3.
Replace
the
power
supply.
Power
supply
current
exceeded
max
spec
value
1.
Install
another
power
supply
(if
possible)
and
make
sure
that
ac
power
cords
are
correctly
connected.
2.
Remove
devices
that
consume
an
extraordinary
amount
of
power.
3.
Replace
the
power
backplane.
Power
Supply
X
12V
Over
Current
Fault
1.
Reseat
the
following
components:
a.
Power
supply
b.
Power
backplane
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
Power
supply
b.
(Trained
service
technician
only)
Power
backplane
88
IBM
System
x3950
Type
8878
and
System
x3950
E
Type
8879:
Problem
Determination
and
Service
Guide