v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Error
code
Description
Action
201-198-000
Memory
Test
Aborted:
Could
not
run
the
test;
suspect
microprocessor
tray
error.
1.
Restart
the
server.
2.
Run
the
diagnostic
test
again.
3.
Reinstall
the
diagnostic
programs
(see
4.
(Trained
service
technician
only)
Replace
the
microprocessor
tray.
201-198-00n
Memory
Test
Aborted:
Could
not
run
the
test.
Note:
n
=
1-9
(programming
error).
1.
Restart
the
server.
2.
Run
the
diagnostic
test
again.
3.
Reinstall
the
diagnostic
programs
(see
201-xxx-CBN
Failed
Memory
Test:
See
v
C
=
memory
card
[1-4]
v
B
=
physical
bank
[1-2]
Note:
Bank
1
=
DIMMs
1
and
3;
Bank
2
=
DIMMs
2
and
4
v
N
=
failing
DIMM
[1-4]
1.
Reseat
the
following
components:
a.
DIMM
N
b.
Memory
card
C
2.
Replace
the
components
listed
in
step
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
Note:
N
=
9
indicates
both
DIMMs
in
physical
bank
B
and
memory
card
C.
202-xxx-0nn
Failed
system
cache
test,
where
nn=APIC
ID.
APIC
ID
(physical
mode)
Microprocessor
00,
01,
02,
03
1
04,
05,
06,
07
2
10,
11,
12,
13
3
14,
15,
16,
17
4
APIC
ID
(logical
mode)
Microprocessor
00,
01,
02,
03
1
24,
25,
26,
27
2
10,
11,
12,
13
3
34,
35,
36,
37
4
1.
Reseat
the
following
components:
a.
(Trained
service
technician
only)
Microprocessor
nn
b.
Microprocessor
tray
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
a.
(Trained
service
technician
only)
Microprocessor
nn
b.
(Trained
service
technician
only)
Microprocessor
tray
204-198-000
Test
aborted.
1.
Run
the
Quick
Memory
Test
Diagnostic
All
Banks
(see
2.
Update
the
BIOS
code
(see
3.
Look
in
the
test
log
(see
and
correct
any
other
errors.
76
IBM
System
x3950
Type
8878
and
System
x3950
E
Type
8879:
Problem
Determination
and
Service
Guide