v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Beep
code
Description
Action
3-3-2
Critical
SMBUS
error
occurred.
1.
Disconnect
power
cord,
wait
30
seconds,
and
retry.
2.
Reseat
the
following
components:
a.
DIMM
b.
Memory
card
c.
Microprocessor
tray
d.
I/O
board
3.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
a.
DIMM
b.
Memory
card
c.
(Trained
service
technician
only)
Microprocessor
tray
d.
I/O
board
3-3-3
No
operational
memory
in
system.
Note:
Make
sure
you
re-enable
the
memory
in
the
Configuration/Setup
Utility
program.
See,
1.
Make
sure
that
all
memory
cards
contain
the
correct
number
of
DIMMs;
install
or
reseat
DIMMS;
then,
restart
the
server.
2.
Reseat
the
following
components:
a.
DIMM
b.
Memory
card
c.
Microprocessor
tray
3.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
a.
DIMM
b.
Memory
card
c.
(Trained
service
technician
only)
Microprocessor
tray
Two
short
beeps
Information
only,
configuration
has
changed.
1.
Run
the
Configuration/Setup
Utility
program.
2.
Run
the
diagnostic
programs.
16
IBM
System
x3950
Type
8878
and
System
x3950
E
Type
8879:
Problem
Determination
and
Service
Guide